English
Language : 

UPD8873 Datasheet, PDF (5/32 Pages) NEC – (5400 ®5400) PIXELS x 3 COLOR CCD LINEAR IMAGE SENSOR
µ PD8873
ABSOLUTE MAXIMUM RATINGS (TA = +25°C)
Parameter
Output drain voltage
Shift register clock voltage
Reset gate clock voltage
Reset feed-through level clamp clock voltage
dpi select signal voltage
Transfer gate clock voltage
Operating ambient temperature Note
Storage temperature
Symbol
VOD
Vφ 1, Vφ 2
Vφ R
Vφ CLB
Vφ SEL
Vφ TG1 to Vφ TG3
TA
Tstg
Note Use at the condition without dew condensation.
Ratings
Unit
−0.3 to +15
V
−0.3 to +8
V
−0.3 to +8
V
−0.3 to +8
V
−0.3 to +8
V
−0.3 to +8
V
0 to +60
°C
−40 to +70
°C
Caution Product quality may suffer if the absolute maximum rating is exceeded even momentarily for any
parameter. That is, the absolute maximum ratings are rated values at which the product is on the
verge of suffering physical damage, and therefore the product must be used under conditions that
ensure that the absolute maximum ratings are not exceeded.
RECOMMENDED OPERATING CONDITIONS (TA = +25°C)
Parameter
Output drain voltage
Shift register clock high level
Shift register clock low level
Reset gate clock high level
Reset gate clock low level
Reset feed-through level clamp clock high level
Reset feed-through level clamp clock low level
dpi select signal high level
dpi select signal low level
Transfer gate clock high level
Transfer gate clock low level
Data rate
Clock pulse frequency
Symbol
VOD
Vφ 1H, Vφ 2H
Vφ 1L, Vφ 2L
Vφ RH
Vφ RL
Vφ CLBH
Vφ CLBL
Vφ SELH
Vφ SELL
Vφ TG1H to Vφ TG3H
Vφ TG1L to Vφ TG3L
fφ R
fφ 1, fφ 2
Min.
11.4
4.75
0
4.75
0
4.75
0
4.75
0
4.75
0
−
−
Typ.
12.0
5.0
0
5.0
0
5.0
0
5.0
0
Vφ 1H Note
0
2.0
2.0
Max.
12.6
5.5
0.15
5.5
0.15
5.5
0.15
5.5
0.15
Vφ 1H Note
0.15
12.5
12.5
Unit
V
V
V
V
V
V
V
V
V
V
V
MHz
MHz
Note When Transfer gate clock high level (Vφ TG1H to Vφ TG3H) is higher than Shift register clock high level (Vφ 1H),
Image lag can increase.
Data Sheet S16614EJ2V0DS
5