English
Language : 

SVHB21V105M Datasheet, PDF (4/20 Pages) NEC – SURFACE MOUNT RESIN MOLDED TANTALUM CHIP CAPACITORS HIGH RELIABILITY
SV/H SERIES
PERFORMANCE
No.
Items
1 Operating Temp. Range –55 to +125°C
Specifications
2 Rated Voltage
10
16
20
25
35
Vdc
3 Surge Voltage
13
20
26
33
46
Vdc
4 Derated Voltage
6.3
10
13
16
22
Vdc
5 Capacitance Range
0.1 to 33 µF
6 Capacitance Tolerance ±20%, ±10%
7 Leakage Current
0.01CV (µA) or 0.5 (µA) whichever is greater
8 Tangent of loss angle 0.1 to 4.7 µF: 0.04 MAX.
6.8 to 33 µF : 0.06 MAX.
9 Surge Voltage
∆C/C
: ±5%
Tangent of loss angle: initial requirement
Leakage Current : initial requirement
10 Charac- Temp.
–55°C
+85°C
+125°C
teristics
at high
∆C/C
and low
temperature Tangent of
loss angle
0
–12 %
0.1 to 4.7 µF: 0.08 MAX.
6.8 to 33 µF : 0.10 MAX.
+12
0%
+15
0%
initial
0.1 to 4.7 µF: 0.06 MAX.
requirement 6.8 to 33 µF : 0.08 MAX.
Leakge
Current
—
0.1 CV or 5 µA 0.125 CV or 6.25 µA
MAX.
MAX.
11 Rapid change of
temperature
∆C/C
: ±10%
Tangent of loss angle: initial requirement
Leakage Current : initial requirement
12 Resistance to
Soldering
13 Damp Heat
(steady state)
14 Terminal Strength
∆C/C
: ±5%
Tangent of loss angle: initial requirement
Leakage Current : initial requirement
∆C/C
: ±10%
Tangent of loss angle: 150% of initial requirement
Leakage Current : initial requirement
There shall be no loosening or permanent damage
15 Endurance (1)
16 Endurance (2)
17 Failure Rate
∆C/C
: ±10%
Tangent of loss angle: initial requirement
Leakage Current : 125% of initial requirement
∆C/C
: ±10%
Tangent of loss angle: initial requirement
Leakage Current : 125% of initial requirement
0.5%/1000 h
Test Conditions
Applied voltage shall be
derated over +85°C
at 85°C
at 125°C
at 120 Hz
Rated Voltage applied
after 5 minutes.
at 120 Hz
at 85°C, Rs = 1 kΩ
1000 cycles
IEC68-2-14 Test N and
IEC68-22-33 Guidance
–55°C to +125°C,
1000 cycles
IEC68-2-58 Test Td
Fully immersion to Solder
260°C, 10 sec
IEC68-2-3 Test Ca
at 85°C, 85% RH,
1000 h
pull of 5N in an axial
direction
at 85°C, Rated Voltage
applied 2000 h
at 125°C, Derated
Voltage applied 2000 h
each condition of No. 15
and No. 16 above
4