English
Language : 

UPG139GV Datasheet, PDF (3/8 Pages) NEC – L-BAND DPDT MMIC SWITCH
µPG139GV
RECOMMENDED OPERATING CONDITIONS (TA = 25°C)
Parameters
Control Voltage (High)
Control Voltage (Low)
Supply Voltage
Input Power (ANT1, 2-TX, VCONT = +5 V)
Input Power (ANT1, 2-RX, VCONT = +5 V)
Input Power (ANT1, 2-TX, VCONT = +3 V)
Input Power (ANT1, 2-RX, VCONT = +3 V)
Symbol
VCONT(H)
VCONT(L)
VDD
Pin
Pin
Pin
Pin
MIN.
+2.7
–0.2
VCONT(H) – 0.7
TYP.
+3.6
0
VCONT(H) – 0.6
MAX.
+5.3
+0.2
VCONT(H) – 0.5
+36
+33
+33
+31
Unit
V
V
V
dBm
dBm
dBm
dBm
ELECTRICAL CHARACTERISTICS
(Unless otherwise specified, TA = 25°C, VCONT = +3.6 V/0 V, VDD = +3.0 V, ZS = ZL = 50 Ω)
Parameters
Insertion Loss 1
Insertion Loss 2
Insertion Loss 3
Insertion Loss 4
Insertion Loss 5
Insertion Loss 6
Isolation 1
Isolation 2
Isolation 3
Isolation 4
Input Return Loss
Output Return Loss
1 dB Compression PointNote
1 dB Compression PointNote
Input Power at 0.5 dB
Compression PointNote
Input Power at 0.5 dB
Compression PointNote
Control Current
Switching Speed
Symbol
LINS1
LINS2
LINS3
LINS4
LINS5
LINS6
ISL1
ISL2
ISL3
ISL4
RLin
RLout
Pin(1 dB)1
Pin(1 dB)2
Pin(0.5 dB)3
Pin(0.5 dB)4
ICONT
tsw
Test Conditions
ANT1, 2-TX, f = 100 M to 1 GHz
ANT1, 2-TX, f = 1.5 GHz
ANT1, 2-TX, f = 2 GHz
ANT1, 2-RX, f = 100 M to 1 GHz
ANT1, 2-RX, f = 1.5 GHz
ANT1, 2-RX, f = 2 GHz
ANT1, 2-TX, f = 100 M to 1.5 GHz
ANT1, 2-TX, f = 2 GHz
ANT1, 2-RX, f = 100 M to 1.5 GHz
ANT1, 2-RX, f = 2 GHz
f = 100 M to 2 GHz
f = 100 M to 2 GHz
ANT1, 2-TX, f = 100 M to 2 GHz
ANT1, 2-RX, f = 100 M to 2 GHz
ANT1, 2-TX, f = 100 M to 2 GHz
VCONT = +5 V/0 V VDD = +5.0 V
ANT1, 2-RX, f = 100 M to 2 GHz
VCONT = +5 V/0 V VDD = +5.0 V
RF OFF
MIN.
13.5
10.5
13.5
10.5
11
11
+32
+27
TYP.
0.70
0.90
1.20
0.85
1.05
1.30
15.5
12.5
15.5
12.5
15
15
+34
+30
+36
+33
15
60
MAX.
0.85
1.00
1.30
0.95
1.15
1.40
Unit
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBm
dBm
50
µA
nS
Note Pin (1 dB) and Pin (0.5 dB) are measured the input power level when the insertion loss increase more 1 dB
or 0.5 dB than that of linear range. All other characteristics are measured in linear range.
3