English
Language : 

E120D-1 Datasheet, PDF (2/3 Pages) NEC – 2 socket server
ENERGY STAR Power and Performance Data Sheet
Express5800/E120d-1
Page 2 of 3
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling
Processor or Core Reduced Power States
Power Capping
Variable Speed Fan Control Based on Power or Thermal Readings
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
Other1:
Other2:
Other3:
Other4:
Enabled on
Shipment
Yes
Yes
No
Yes
No
No
No
End-User Enabling
Required
No
No
Yes
No
No
No
No
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?
Input Air Temp Available & Accuracy?
Processor Utilization Available?
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection
Averaging method and time period
Yes, +/- 5%
Yes, +/- 2 degree C
Yes
IPMI
Non Averaging, 1 sec. interval sampling
Thermal Information *
Total Power Dissipation (watts)
Delta Temperature at Exhaust at Peak Temp. (˚C)
Minimum
126.9W
3.8
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
24.7
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
22.0
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008
Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
Peak temperature is defined as 35 ˚C, Nominal Tempera
Typical
170.5W
4.9
24.7
23.8
Maximum
233.7W
6.8
27.0
20.9
Notes
1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on
XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org
ENERGY STAR Qualified Configurations
Include specific information on ENERGY STAR Qualified SKUs or configurations
Qualified Configuration ID: N8100-1911Y/1914Y