English
Language : 

E120D-1 Datasheet, PDF (1/3 Pages) NEC – 2 socket server
ENERGY STAR ® Power and Performance Data Sheet
Express5800/E120d-1
System Characteristics
Form Factor
Available Processor Sockets
Available DIMM Slots / Max Memory Capacity
ECC and/or Fully Buffered DIMMs
Available Expansion Slots
Minimum and Maximum # of Hard Drives
Redundant Power Supply Capable?
Power Supply Make and Model
Power Supply Output Rating* (watts)
Minimum and Maximum # of Power Supplies
Input Power Range (AC or DC)
Power Supply Efficiency at Specified Loadings*
Power Supply Power Factor at Specified Loadings*
Operating Systems Supported
Installed Operating System for Testing
* Note: Power supply information is for a single power supply only
2 socket server
2
12slots / 384GB max.
Yes
2 PCI-E 3.0
0 to 8
No
Delta Electronics DPS-400AB-12 G
400W
1
100-200VAC
88.0@20%, 91.9@50%, 91.6@100%
0.90@20%, 0.97@50%, 0.98@100%
VMware ESX 4.1
Microsoft Windows Server 2008 R2 Standard
System Configurations
Configuration ID
Processor Information
Memory Information
Internal Storage
I/O Devices
Power Supply Number and Redundancy Configuration
Management Controller or Service Processor Installed?
Other Hardware Features / Accessories
Minimum
N8100-1914Y
Intel Xeon E5-2430L
2.0GHz x2
DDR3-1600
2GB x2
SATA 6Gbps 7200rpm
250GB x1
None
DPS-400AB-12G
400W x1
Yes
Typical
N8100-1914Y
Intel Xeon E5-2430L
2.0GHz x2
DDR3-1600
32GB x6
SAS 6Gbps 10000rpm
900GB x3
SAS Raid Card x1
DPS-400AB-12G
400W x1
Yes
Maximum
N8100-1914Y
Intel Xeon E5-2430L
2.0GHz x2
DDR3-1600
32GB x12
SAS 6Gbps 10000rpm
900GB x8
SAS Raid Card x1
Ethernet card x1
DPS-400AB-12G
400W x1
Yes
Power Data
Idle Category (1S and 2S only)
Minimum
Typical
Maximum
Category D: Managed Dual Installed Processor (2P) Servers
ENERGY STAR Idle Power Allowance (1S and 2S only)
150W
206W
1006W
Measured Idle Power (watts)
59.8
101.3
159.6
Power at Full Load* (watts)
Benchmark / Method Used for Full Load Test
Test Voltage and Frequency for Idle and Full Load Test
126.9
170.5
233.7
Use SiSoftware Sandra Engineer (.NET Multi-Media)
230V / 60Hz
Range of Total Estimated Energy Usage ** (kWh/year)
1048 to 2223
1775 to 2987
2796 to 4094
Link to Detailed Power Calculator (if available)
* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the
highest average, sustained power possible for other workloads.
** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100%
full load operation. The calculation also includes typical data center overhead at a ratio
Power and Performance for Benchmark #1
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
Power and Performance for Benchmark #2 (optional)
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
Minimum
Typical
Maximum
SiSoftware Sandra Engineer (.NET Multi-Media)
126.9W
170.5W
233.7W
53.56Mpixel/s
53.51Mpixel/s
53.27Mpixel/s
0.42
0.31
0.23
N/A
N/A
N/A
Minimum
Typical
Maximum