English
Language : 

MVAC250_13 Datasheet, PDF (8/8 Pages) Murata Manufacturing Co., Ltd. – 250W High Density AC-DC Power Supply
MECHANICAL DIMENSIONS – MVAC250-xxAF AND MVAC250-xxAFD MODELS
6.35±0.13
.250±.005
6.50±0.13
.256±.005
MTG1
127.00±0.25
5.000±.010
114.30±0.13
4.500±.005
MTG4
76.20±0.25
3.000±.010
TB1
J1
PIN 1
PIN 2
REMOVED
63.50±0.13
J1
2.500±.005 PIN 3
PRIMARY
HEATSINK
NOTE 3 !
30.0±0.25
1.181±.010
MTG2
MTG3
MVAC250 Series
250W High Density AC-DC Power Supply
J2
PIN12
J2
PIN1
J3
PIN 1
J3
PIN 8
MOUNTING HOLES
3.96±0.13
.156±.005
MAX SCREW HEAD
J2 DIAMETER 7.40
6 12 1-6
+DC_OUT
5 11 7-12 +DC_OUT_RTN
4 10
39
28
17
J3
21
43
65
87
1
+5V_AUX
2
PWR_OK
3 +12V_FAN_RTN
4
PS_ON
5 +REMOTE SENSE
6 -REMOTE SENSE
7
+12V_FAN
8 +5V_AUX_RTN
5.56±0.13
.219±.005
ALL DIMENSIONS ARE IN MM [IN]. TOLERANCE IS ±0.65MM [0.025IN]
SAFETY CONSIDERATION NOTES:
1. Protective bonding conductor from the end product protective earthing terminal must be tied to TB1. For optimum EMI performance, 4 mounting holes
must be tied to the end product protective earthing terminal.
2. This power supply requires mounting on standoffs minimum 6mm in height. If there is risk of chassis deformation or shorter standoff height is
required, an appropriate insulator must be used under the power supply with adequate extension beyond the outline of the power supply. In all cases,
the applicable safety standards must be applied to ensure proper creepage and clearance requirements are met.
3. The primary heatsink is considered a live primary circuit, and should not be touched. Also, the primary and secondary heatsinks must be separated
with reinforced insulation. It is recommended that the primary heatsink be kept at least 3.5mm from chassis and 7mm from secondary circuits. In all
cases, the applicable safety standards must be applied to ensure proper creepage and clearance requirements are met.
4. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to:
http://www.murata-ps.com/requirements/
Dimensions: 3.0" x 5.0" x 1.4" (76.2mm x 127mm x 35.6mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS – MVAC250-xxAF AND MVAC250-xxAFD MODELS
Connector
PIN
Description
Mating Housing
Crimp terminal/pins
Input Connector J1 : 1
Molex 26-62-4030
3
AC Neutral
AC Line
Molex 0009930300
Molex 0008500105 (18-24 AWG)
Molex 0008500107 (22-26 AWG)
Output Connector J2 : 1,2,3,4,5,6
Molex 39-28-1123
7,8,9,10,11,12
+DC_OUT
+DC_OUT_RTN
Molex 0039012125
Molex 0039000038
1
+5V_AUX
2
PWR_OK
3
+12V_FAN_RTN
Output Connector J3: 4
Molex 90130-1108
5
PS_ON
+ Remote Sense
Molex 0901420008
Molex 0901190109
6
- Remote Sense
7
+12V_FAN
8
+5V_AUX_RTN
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
MVAC250.A03 Page 8 of 8