English
Language : 

MVAC250_13 Datasheet, PDF (3/8 Pages) Murata Manufacturing Co., Ltd. – 250W High Density AC-DC Power Supply
MVAC250 Series
250W High Density AC-DC Power Supply
EMISSIONS AND IMMUNITY
Characteristic
Input Current Harmonics
Voltage Fluctuation and Flicker
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Radiated Field Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
Standard
IEC/EN 61000-3-2
IEC/EN 61000-3-3
EN 55022
FCC Part 15
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Compliance
Class A
Complies
Class B
Class B
Level 4, Criterion 2
Level 3, Criterion A
Level 4, Criterion A
Level 3, Criterion A
Level 3, 10V/m, Criterion A
Level 3, Criterion A
Level 3, Criterion B
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply
with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the
stand-alone power supply to comply with EN55022 class A radiated emissions. Class B radiated emissions are achievable with a metal enclosure. Radi-
ated emission results vary with system enclosure and cable routing paths.
STATUS AND CONTROL SIGNALS – MVAC250-xxAFD ONLY
Parameter Conditions
PS_ON This signal must be sinked low (>2mA) to +5V_AUX_RTN to turn on the main and Fan (V2) output. The +5V_AUX output is on when AC is applied.
PWR_OK
Open collector logic goes high 50-200 msec after main output is in regulation; it goes low at least 6 msec before loss of regulation. Internal 10K pull up to +5V_AUX is
provided. Applications using PWR_OK signal should maintain a minimum load of 5W on the main or fan output.
1. Noise and ripple is measured at an oscilloscope jack on the output, 20MHz bandwidth, and with
0.1µF ceramic and 10µF aluminum electrolytic capacitors across the output pins.
2. Unless otherwise specified all measurements are taken at 120Vac input and 25°C ambient
temperature.
3. Fan (V2) regulation band applies from 0.1A to 1A load with a minimum of 10W load on the main
(V1) output.
4. Fan (V2) has overvoltage protection (tracking V1) and short circuit protection. Overloading the Fan
(V2) output can result in permanent damage to the unit.
5. 24V and 50V models may exhibit up to 5% turn on overshoot for loads less than 4% of full load.
6. See current sharing option section for droop characteristics.
7. No load Input power varies by model and by input line. Measurement is difficult to make due to burst
mode operation. Please contact Murata sales if additional information is required.
8. All three output returns are isolated from each other (see isolation characteristics section); the returns
may be tied together externally.
9. Load steps beginning from combined loads on the main and fan outputs of less than 5W may
result in transient undershoots outside of the spec limits.
www.murata-ps.com/support
MVAC250.A03 Page 3 of 8