English
Language : 

DE2E3KH102MN3A Datasheet, PDF (50/72 Pages) Murata Manufacturing Co., Ltd. – Safety Certified Ceramic Capacitors/ High Voltage Ceramic Capacitors
C85E.pdf !Note • Th!is PNDoFteca•taPlolegasisedroewadnlroaatdinegdafnrodm!thCeAwUeTbIOsiNte(ofof rMsutoraratageM, aonpuefraactitnugri,nrgatcinog.,,ltsdo.ldTehreinregf,omreo,uint’tsinsgpaencdifichaatniodnlisnga)reinstuhbisjeccatttaolocghatongpereovreonut rsmprookdiuncgtsanind/iot rmbauyrnbiengd,isectco.ntinued without advance notice. Please check with our
sales repres•enTthaistivceastaolor gprhoadsucotnelyntgyipniecearlsspbeecfoifriceaotirodnesribnegc. ause there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
08.10.29 • This PDF catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
DEB Series Specifications and Test Methods
Continued from the preceding page.
No.
Item
Specifications
Test Method
Appearance
Capacitance
Change
No marked defect
Char. B: Within ±5%
Char. E: Within ±15%
Char. F: Within ±20%
13 Soldering Effect
(On-Preheat)
Dielectric Strength
(Between Lead
Wires)
Per item 4.
First the capacitor should be
stored at 120+0/-5°C for
60+0/-5 sec.
Then, as in figure, the lead wires
should be immersed in solder of
260+0/-5°C up to 1.5 to 2.0mm
from the root of terminal for
Thermal
, Capacitor
Scree,,n,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,M1too.l5t2e.n0mm
Solder
7.5+0/-1 sec.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition*.
Appearance
Capacitance
Change
D.F.
I.R.
Temperature
14 and Immersion
Cycle
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 4.0% max.
Char. F: 7.5% max.
2000MΩ min.
Dielectric Strength
(Between Lead
Wires)
Per item 4.
The capacitor should be subjected to 5 temperature cycles,
then consecutively to 2 immersion cycles.
<Temperature Cycle>
Step
1
2
3
4
Temperature (°C)
-25±3
Room Temp.
85±3
Room Temp.
Time (min)
30
3
30
3
<Immersion Cycle>
Cycle time: 5 cycle
Step Temperature (°C) Time (min) Immersion Water
1
65+5/-0
15
Clean water
2
0±3
15
Salt water
Cycle time : 2 cycle
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 4 to 24 hrs. at
room condition*.
Appearance
Capacitance
9
15
Humidity (Under
Steady State)
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 5.0% max.
Char. F: 7.5% max.
1000MΩ min.
Set the capacitor for 500+24/-0 hrs. at 40±2°C in 90 to 95%
relative humidity.
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored for 1 to 2 hrs. at
room condition*.
16
Humidity
Loading
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 5.0% max.
Char. F: 7.5% max.
500MΩ min.
Apply the rated voltage for 500+24/-0 hrs. at 40±2°C in 90 to
95% relative humidity. (Charge/Discharge currentV50mA)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
17 Life
Appearance
Capacitance
Change
D.F.
I.R.
No marked defect
Char. B: Within ±10%
Char. E: Within ±20%
Char. F: Within ±30%
Char. B, E: 4.0% max.
Char. F: 7.5% max.
2000MΩ min.
Apply a DC voltage of 150% of the rated voltage for
1000+48/-0 hrs. at 85±2°C with a relative humidity of 50% max.
(Charge/Discharge currentV50mA)
Pre-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
before initial measurements.
Post-treatment: Capacitor should be stored at 85±2°C for 1 hr.,
then placed at room condition* for 24±2 hrs.
* "room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
48