English
Language : 

DSS6NB32A471Q55B Datasheet, PDF (34/40 Pages) Murata Manufacturing Co., Ltd. – EMI Suppression Filters (Lead Type EMIFIL)
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
!Caution/Notice
!Caution
o Rating
Do not use products beyond the rated current and rated voltage as this
may create excessive heat and deteriorate the insulation resistance.
o Soldering and Mounting
1. Mounting holes should be designed as specified in these
specifications. Other designs than those shown in these
specifications may cause cracks in ceramics that may
lead to smoking or firing.
2. DSN9/DST9/DSN9H/DST9H/VFS9V Series
Mounting for PCB. (Applis only to bulk type.)
The form of the mounting hole of the bulk item is a triangle.
The product should be inserted and soldered to each hole in
the correct way as in Fig.1. (The center terminal and the other
terminals become parallel when viewing the product from the
side.) Smoking and firing maybe caused by incorrect mounting
as in Fig.2. (The center terminal and the other terminals cross
when viewing the product from the side.)
Marking Side
Center Terminal
(Ground Terminal)
Fig.1 Right Way
Fig.2 Wrong Way
3. Take care not to apply any mechanical stress to product
body at the lead terminal bending process for product
angle adjustment after insertion.
For DST9, please do not bend the lead terminal at the
point between the dielectric part and the ferrite bead.
Notice
o Storage and Operating Conditions
<Operating Environment>
2. Products should be used at rated voltage or less and
1. Do not use products in a chemical atmosphere such
rated current or less.
as chlorine gas, acid or sulfide gas.
3. Products should not be applied for the absorption of
2. Do not use products near water, oil or organic
surges that have large energy (e.g., induced lightning
solvents. Avoid environments where dust or dirt may
surges, switching surges) because it is designed for the
adhere to the product.
absorption of electrostatic surges (VFR3V).
<Storage and Handling Requirements>
4. Electrostatic testing should be done on the following
1. Storage Period
conditions (VFR3V).
Use the products within 12 months after delivery.
Ns;#2s62 ]2 < 8.0 x105
Solderability should be checked if this period is
n: Times applied
exceeded.
C: Charging Capacitance (pF)
2. Storage Conditions
V: Testing Voltage (kV)
(1) Storage temperature: -10 to 40 degrees C
R: Charging Resistance (Ω)
Relative humidity: 15 to 85%
Avoid sudden changes in temperature and humidity.
o Soldering and Mounting
(2) Do not store products in a chemical atmosphere
1. Washing
such as chlorine gas, acid or sulfide gas.
Failure and degradation of a product are caused
(3) When restoring taping type (BL01RN1A1F1J),
by the washing method. When you wash in conditions
please attach the spacer between the flanges of the
that are not in the mounting information, please contact
reel. The spacer is corrugated paper that is attached
Murata engineering.
when shipping.
2. Soldering
<Using EMIGUARDr effectively>
Reliability decreases with improper soldering
1. Terminal (with mark) should be properly connected to
methods. Please solder by the standard soldering
the line of incoming electrostatic surge. (There is
conditions shown in the mounting information.
polarity.) Otherwise, no effect in ESD suppression can
3. Other
be expected (VFR3V).
Noise suppression levels resulting from Murata's
Example of input terminal Example of output terminal
EMI suppression filters EMIFILr may vary, depending
on the circuits and ICs used, type of noise, mounting
Incoming
Electrostatic Surges
Incoming
Electrostatic Surges
pattern, lead wire length, mounting location, and other
operating conditions. Be sure to check and confirm in
advance the noise suppression effect of each filter, in
actual circuits, etc. before applying the filter in a
commercial-purpose equipment design.
32