English
Language : 

RUW15 Datasheet, PDF (1/5 Pages) Murata Manufacturing Co., Ltd. – Isolated Ultra-Wide Input DC/DC Converters
www.murata-ps.com
RUW15 Series
Isolated Ultra-Wide Input DC/DC Converters
FEATURES
„ UL 60950 recognized for reinforced
insulation pending
„ High transient voltage withstand capability
„ Ultra wide input voltage range of
16-160VDC
„ Externally settable hold up time with
additional capacitor
„ DC OK/Power Fail signal
„ Short circuit protection
„ Over Temperature protection
„ Over voltage protection
DESCRIPTION
The RUW series is particularly suitable for use
in applications in railway, industry or telecom-
munication where variable input voltages or
high transient voltages are present. With an ultra
wide input voltage range of 16-160VDC, the
RUW series is capable of withstanding surges
from 24,36,48,72, 90 and 110V systems, largely
eliminating the requirement for input protection
circuitry.
Optional features include a Power Fail/DC OK
signal and circuitry to facilitate long hold-up times
with a small external capacitor across ±Vint pins.
SELECTION GUIDE
Order Code1
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
Input Voltage
Nom.
SL
SL
SL
SL
Output
Voltage
V
12
12
24
24
Output Current
Min.
Max.
A
A
0.125
1.25
0.125
1.25
0.0625
0.625
0.0625
0.625
Output Power
Max.
W
15
15
15
15
MTTF3
kHrs
1550
959
1094
1176
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range2
Continuous operation SL I/P types
Input standby current
Min. Typ. Max. Units
16
160
V
10
mA
INPUT CURRENT (10% Load)
Order Code
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
16
0.135
0.146
0.160
0.146
24
0.088
0.093
0.102
0.098
48
0.044
0.048
0.053
0.049
Input Voltage
60
72
96
0.035 0.030 0.023
0.038 0.032 0.025
0.043 0.036 0.029
0.039 0.033 0.027
110
0.022
0.024
0.028
0.025
132
0.018
0.021
0.025
0.022
160
0.015
0.018
0.021
0.018
Units
V
mAp-p
INPUT REFLECTED RIPPLE
Order Code
RUW15SL12C
RUW15SL12HC
RUW15SL24C
RUW15SL24HC
16
332.8
292.4
406.4
446.4
24
309.2
236.8
387.6
291.2
Input Voltage
48
72
184.8
155.2
142.4
107
249.6
195.6
176.4
157.2
110
138.8
86.5
167.5
101.8
160
119.6
76.3
138.8
82.7
Units
V
mAp-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Voltage set point error
Overall voltage envelope
RUW15SL12C
Line regulation
RUW15SL12HC & RUW15SL24HC
RUW15SL24C
Load regulation
10-100% Load
Ripple & noise
BW = 20MHz
(24VIN to 110VIN)
12VOUT types
24VOUT types
Transient response
Peak deviation (20-100% & 100-20% swing)
Settling time
Start delay
From remote on/off RUWSLXXC
From application of VIN RUWSLXXC
Overvoltage protection
Short circuit protection Continuous
Min. Typ. Max.
0.8
1.5
3.0
0.5
0.2
0.25
0.25
3.0
1.5
TBD
TBD
110%
1. Part numbers ending HC include optional Power Fail /DC OK signal and circuitry to facilitate long hold up time.
2. Will operate down to 14V for 100ms as required by EN 50155 (24V system).
3. Using Telecordia Issue 1 method I case 1 operating temperature 25C
All specifications typical at TA=25°C and rated output current unless otherwise specified.
Units
%VOUT
%VOUT
%
%
mVp-p
%VOUT
ms
ms
VOUT
Ḥ
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_RUW15.A01 Page 1 of 5