FEATURES
110W Wide Operating Temperature range
AC-DC Power Supply
IT (2nd Ed.) and Medical (3rd Ed. MOPP) safety
approved, excluding conduction cooling condi-
tion
2" x 4" standard footprint
High efficiency up to 93%
Remote sense
Remote On/Off (for V1, Negative logic)
Universal AC input
Low profile - 1U package
Convection, conduction, and forced-air cooled
operation
Complies with 5000m altitude (at class I IT
equipment)
RoHS compliant
Less than 0.3W input power at no load remote
“off”
Complies with ErP/Energy star requirement
(average efficiency > 87%)
Available now at
http://power.murata.com/acdc3d
hptotwp:e/r/.pmouwreart.am.cuormata.com
MVAD160 Series
160W 2" X 4" AC-DC Power Supply Converter
DESCRIPTION
The MVAD160 series switching power supplies utilize advanced component and circuit technologies
to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U
height design considerations, the MVAD160 Series measures only 2.0" x 4.0" x 1.5". All models offer
universal AC input and compliance to worldwide safety and EMC standards.
ORDERING GUIDE
Model Number
Natural Convection Conduction Cooling Forced Air Cooling Main
Cooling (@ta = 50°C) (@ta = 85°C) (@350LFM /ta=50°C) Output (V1)
Aux Output (V2)
MVAD160-125
12V
MVAD160-245
24V
5V
MVAD160-485
MVAD160-12
110W
110W
160W
48V
12V
no aux output
MVAD160-24
24V no remote sense
MVAD160-48
48V
no V1 remote
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
Inrush Current
Conditions
Min. Typ. Max. Units
Single phase
851 120/230 264
Vac
DC2
200
300 Vdc
47 50/60 63
Hz
Input rising at full load
Input falling at full load
84
84
Vac
90Vac input, full load
2.1
A
At 264Vac, at 25°C cold start
100
Apk
OUTPUT CHARACTERISTICS
Model Number
Main Output
Voltage (V1)
MVAD160-12x
12V
MVAD160-24x
24V
MVAD160-48x
48V
Model Number
Aux Output
Voltage (V2)
MVAD0160-xx5
5V
Load Current
0 to 13.34A
0 to 6.67A
0 to 3.34A
Load Current
0 to 0.1A
Load Capacitance
0 to 1500μF
0 to 680μF
0 to 330μF
Load Capacitance
0 to 220pF
Line, Load, Cross
Regulation
± 2%
Line, Load,
Cross Regulation
± 5%
Typical Efficiency
@230Vac full load
92%
93%
Main Output Characteristics (all models)
Parameter
Transient Response
Conditions
Min. Max. Units
50% load step, min.5% load, 1A/μsec slew rate
± 5 %V1
Settling Time to 1% of Nominal
Turn On Delay
Output Voltage Rise
Setpoint Accuracy
50% load step, min.5% load, 1A/μsec slew rate
After application of input power
Monotonic,5 0 to 100% load
115Vac, 110W load, 25°C
2
1.5
200
± 0.5
msec
sec
msec
%V1
Output Holdup
100% load
10
msec
Temperature Coefficient
Ripple Voltage & Noise3
min. 5% load
0.02 %/°C
1
%V1
Compensates for up to total 400mV of positive
Remote Sense
and negative lead drops with remote sense
400
mV
connected.
1 Refer to power derating curve vs. input voltage. Input test condition on safety approval : 100-240Vac ±10%.
2 Applicable for IT Equipment only.
3 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50Ω scope termination is used.
4 Unless otherwise specified all readings are taken at 115Vac input and 25°C ambient temperature.
5 This power supply may exhibit up to 5% turn on overshoot.
CB
Test Certificate
and Test Report
MVAD160.A04 Page 1 of 6