SLC100 Datasheet, PDF (8/9 Pages) C&D Technologies – 40 Amp SINGLE OUTPUT QUARTER BRICK DC / DC CONVERTER
SLC100 1.2VOUT ELECTRICAL SPECIFICATIONS
Specifications are at TA = +25°C, Airflow = 300LFM (1.5m/s) at nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Maximum Input Current
Full Load; Vin = 36Vdc
1.80
A
Inrush Charge
Reflected Ripple Current
Input Voltage Ripple Rejection
No Load Input Current
Vin = 75Vdc
Full Load, XXMhz Bandwidth
Full Load (100Hz-1KHz)
-30
No Load
0.180
TBD
55
mC
mApk-pk
dB
mA
Disabled Input Current
3.0
mA
Quiescent Input Current
2
mA
Recommended Input Fuse
Fast blow external fuse
7
A
OUTPUT
Voltage Setpoint
Voltage Range
Line Regulation
Load Regulation
Output Ripple
Output Current Range
Output Current Limit Inception
Efficiency
Transient Response
Peak Deviation
Settling Time
External Load Capacitance
Rated Power
Over all conditions of line,
load and temperature
1.182
TBD
Vdc
0
44
50% to 75% Load Step at di/dt
=0.1 A/mS; Cext =TBD
1.2
0.05
0.25
100
80
1.218
Vdc
TBD
0.10
0.50
120
401
48
TBD
% of Vnom
% of Vnom
mVpk-pk
A
A
%
TBD
mV
TBD
mS
50,000
mF
48
W
* Note 1: Maximum output current for SMD Models is 25A.
8