English
Language : 

SLC100 Datasheet, PDF (2/9 Pages) C&D Technologies – 40 Amp SINGLE OUTPUT QUARTER BRICK DC / DC CONVERTER
ABSOLUTE MAXIMUM RATINGS, ALL MODELS
PARAMETER
Input Voltage-Operating
Input Voltage-Operating
Operating Ambient Temperature
Storage Temperature
Output Short Circuit Duration
CONDITIONS
Continuous
Transient (100 mS)
MIN
-40
-40
Lead Temperature (Soldering, 10 sec max)
TYP
Continuous
MAX
75
TBD
+100
+125
+300
UNITS
VDC
VDC
°C
°C
°C
COMMON ELECTRICAL SPECIFICATIONS, ALL MODELS
Specifications are at TA = +25°C, Airflow = 300LFM (1.5m/s) at nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
ISOLATION
Input/Output Isolation Voltage
Capacitance
Resistance
FEATURES
Turn On Time
Remote Sense Compensation
Output Voltage Trim Range
Output Over Voltage Protection
Input to Output
Input to Output
Output to within 1% of Vnom
36
2000
10
-10
+120
48
2000
75
VDC
VDC
pF
MW
5.00 mS
5
% of VNOM
+10
% of VNOM
+140
% of VNOM
Over Temperature Shutdown
Shutdown
Turn On
Input Under Voltage Protection
Turn Off
Turn Off
Lockout Hysteresis Voltge
ON/OFF Logic Function
Logic Low Ion/off
Logic Low Von/off
Logic High Ion/off
Logic High Von/off
TBD
°C
TBD
°C
31.50
32.50
0
32.50
33.70
2.2
VDC
VDC
VDC
mA
TBD
VDC
0.8
μA
Open
TBD
VDC
Collector
GENERAL
Switching Frequency
MTTF (per Telcordia TR-NWT-000332)
TBD
TBD
200
KHz
Hrs
2