English
Language : 

D1U3CS-W-1200-12-HXXC Datasheet, PDF (5/6 Pages) Murata Power Solutions Inc. – 81mm 1U Front End AC-DC Power Supply Converter
D1U3CS-W-1200-12-HxxC Series
81mm 1U Front End AC-DC Power Supply Converter
WIRING DIAGRAM FOR OUTPUT
D1U3CS
+12VRS (Main Output Remote Sense)
Dotted lines show optional remote sense connections.
Optional remote sense lines can be attached to a load that is a distance
away from the power supply to improve regulation at the load.
+12VRS (Main Output Remote Sense)
B2
+12V OUT
PB4-6
PB1-3 +12V GND
A2 +12VRS_RETURN
B3 +12V_ISHARE
12V load
+12V OUT PB4-6 B2
+12V GND PB1-3
+12VRS_RETURN A2
+12V_ISHARE B3
D1U3CS
A5,B5,C5,D5
A1
A6,B6,C6,D6
+VSB
PS_ON_L
+VSB GND
+VSB load
FET, BJT, wire
or switch (debounced )
to turn on +12V main output
+VSB A5,B5,C5,D5
PS_ON_L A1
+VSB GND A6,B6,C6,D6
B4 PS_INHIBIT/PS_KILL
PS_INHIBIT/PS_KILL B4
CURRENT SHARING NOTES
12V Output: Current sharing is achieved using the active current share method. (See wiring diagram for connection details.)
Current sharing can be achieved with or without remote sense connected to the common load.
+VSB outputs can be tied together for redundancy but total combined output power must not exceed 20W. The +VSB output has internal ORing MOSFET for additional redundancy /
internal short protection.
The current share pin B3 is a connection between the two units. It is input and/or output as the voltage on the line controls the current share. A power supply will respond to a change
in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit this would read 8V at 100% load. For two units sharing load then
this should read 4V for perfect current sharing.
Up to 8 units can be paralleled together. Please consult your Murata sales representative if operation with more than 8 units in parallel is needed.
www.murata-ps.com/support
D1U3CS-W-1200-12-HxxC.B01 Page 5 of 6