English
Language : 

D1U-H-2800-52-HBXC Datasheet, PDF (3/5 Pages) Murata Power Solutions Inc. – AC/DC Front End Power Supply
CONTROL SIGNALS
Status
LED
FANS MONITORING
Status
Fans monitoring is available through the I2C interface
EMISSIONS AND IMMUNITY
Characteristic
Harmonics
Voltage Fluctuation and Flicker
Emission Conducted
Emission Radiated
ESD
Electromagnetic Field
Electrical Fast Transients/Burst
Surge
RF Conducted Immunity
Magnetic Immunity
Voltage dips, interruptions
D1U-H-2800-52-HBxC Series
AC/DC Front End Power Supply
Conditions
Off
Flashing Yellow
Flashing Green
Green
Conditions
Both fans running normally
One fan failed (or rotor locked)
Both fans failed (or rotors locked)
Description
No AC input to all PS
Power Supply Failure
Main Output Absent
Power Supply Good
Description
PS_Fault0 bits 3 and 4 set to “0”
PS_Fault0 bit 4 set to “1”
PS_Fault0 bits 3 and 4 set to “1”
Description
IEC/EN 61000-3-2
IEC/EN 61000-3-3
FCC 47 CFR Parts 15/CISPR 22/EN55022
FCC 47 CFR Parts 15/CISPR 22/EN55022
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Criteria
Class A, 6dB margin
Class A, 6dB margin
4kV contact discharge
8kV operational air discharge
15kV non-operational air discharge
1kV/2kV, Performance Criteria B
3 Vac, 80% AM, 1kHz, Performance Criteria A
3 A/m
www.murata-ps.com/support
D1U-H-2800-52-HBxC.A08 Page 3 of 5