HPR1000C Datasheet, PDF (2/4 Pages) Murata Power Solutions Inc. – 1.0 WATT UNREGULATED, SIP DC/DC CONVERTER | |||
|
◁ |
HPR10XXC
ELECTRICAL SPECIFICATIONS
1.0 WATT UNREGULATED, SIP DC/DC CONVERTER
Speciï¬cations typical at TA = +25°C, nominal input voltage, rated output current unless otherwise speciï¬ed.
NOMINAL
INPUT
VOLTAGE
RATED
OUTPUT
VOLTAGE
RATED
OUTPUT
CURRENT
INPUT CURRENT
NO LOAD
RATED LOAD
REFLECTED
RIPPLE
CURRENT
EFFICIENCY
MODEL
(VDC)
(VDC)
(mA)
(mA)
(mA)
(mAp-p)
(%)
HPR1000C
5
5
200
33
290
8
68
HPR1001C
5
12
83
33
290
8
69
HPR1002C
5
15
67
33
285
8
70
HPR1003C
5
±5
±100
33
285
8
70
HPR1004C
5
±12
±42
33
285
8
70
HPR1005C
5
±15
±34
33
285
8
70
HPR1006C
12
5
200
18
110
10
70
HPR1007C
12
12
83
18
107
10
71
HPR1008C
12
15
67
18
107
10
71
HPR1009C
12
±5
±100
18
107
10
71
HPR1010C
12
±12
±42
18
107
10
71
HPR1011C
12
±15
±34
18
107
10
71
HPR1012C
15
5
200
15
96
10
70
HPR1013C
15
12
83
15
94
10
70
HPR1014C
15
15
67
15
94
10
71
HPR1015C
HPR1016C
15
±12
±42
15
94
10
71
HPR1017C
15
±15
±34
15
94
10
71
HPR1018C
24
5
200
12
60
15
71
HPR1019C
24
12
83
12
60
15
71
HPR1020C
24
15
67
12
58
15
72
HPR1021C
24
±5
±100
12
58
15
72
HPR1022C
24
±12
±42
12
58
15
72
HPR1023C
24
±15
±34
12
58
15
72
Note: Other input to output voltages may be available. Please contact factory.
COMMON SPECIFICATIONS
Speciï¬cations typical at TA = +25°C, nominal input voltage, rated output current unless otherwise speciï¬ed.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
Voltage Rise Time
4.5
5
5.5
VDC
10.8
12
13.2
VDC
13.5
15
16.5
VDC
21.6
24
26.4
VDC
See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Ripple & Noise
Voltage
Temperature Coefï¬cent
60 Hz, 10 Seconds
VISO= 240VAC, 60Hz
1000
1000
10
25
2
1.0
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
30
1mA Load, VOUT = 5V
1mA Load, V = 12V
OUT
1mA Load, V = 15V
OUT
.01
REGULATION
Line Regulation
High Line to Low Line
1
Load Regulation (5V out only)
Rated Load to 1mA Load
10
Load Regulation (All other Models)
Rated Load to 1mA Load
3
GENERAL
Switching Frequency
170
Frequency Change
Over Line and Load
24
Package Weight
2
MTTF per MIL-HDBK-217, Rev. E
Circuit Stress Method
Ground Benign
TA = +25°C
3.8
Fixed Ground
TA = +35°C
1.4
Naval Sheltered
TA = +35°C
685
Airborne Uninhabited Fighter
TA = +35°C
211
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-20
2
VDC
Vpk
GΩ
100
pF
8.5
μArms
W
±5
%
100
mVp-p
mVrms
7
VDC
15
VDC
18
VDC
%/Deg C
%/%Vin
%
%
kHz
%
g
MHr
MHr
kHr
kHr
TEMPERATURE
Speciï¬cation
Storage
* For demonstrated MTTF results reference Reliability Report HPR105
-25
+25
+65
°C
-50
+110
°C
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
TDC_HPR10XXC.C00 Page 2 of 4
|
▷ |