English
Language : 

3000-XC6DT2-STANDBY Datasheet, PDF (3/4 Pages) MTU Onsite Energy Corporation – DIESEL GENERATOR SET
3 / //  / 3000-XC6DT2
APPLICATION DATA
//  Engine
//  Fuel Consumption
Manufacturer
Model
Type
Arrangement
Displacement: L (in3)
Bore: cm (in)
Stroke: cm (in)
Compression Ratio
Rated RPM
Engine Governor
Maximum Power: kWm (bhp)
Speed Regulation
Air Cleaner
MTU
20V 4000 G83L 6 ECT
4-Cycle
20-V
95.4 (5,822)
17 (6.69)
21 (8.27)
16.4:1
1,800
Electronic Isochronous (ADEC)
3,490 (4,678)
±0.25%
Dry
//  Liquid Capacity (Lubrication)
Total Oil System: L (gal)
Engine Jacket Water Capacity: L (gal)
After Cooler Water Capacity: L (gal)
System Coolant Capacity: L (gal)
390 (103)
205 (54.2)
30 (7.9)
860 (227)
At 100% of Power Rating: L/hr (gal/hr)
At 75% of Power Rating: L/hr (gal/hr)
At 50% of Power Rating: L/hr (gal/hr)
//  Cooling - Radiator System
Ambient Capacity of Radiator: °C (°F)
Maximum Allowable Static
Pressure on Rad. Exhaust: kPa (in. H20)
Water Pump Capacity: L/min (gpm)
After Cooler Pump Capacity: L/min (gpm)
Heat Rejection to Coolant: kW (BTUM)
Heat Rejection to After Cooler: kW (BTUM)
Heat Radiated to Ambient: kW (BTUM)
Fan Power: kW (hp)
//  Air Requirements
//  Electrical
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
//  Fuel System
24
4,200
Aspirating: *m3/min (SCFM)
Air Flow Required for Rad.
Cooled Unit: *m3/min (SCFM)
Remote Cooled Applications;
Air Flow Required for Dissipation
of Radiated Gen-set Heat for a
Max of 25 °F Rise: *m3/min (SCFM)
Fuel Supply Connection Size
Fuel Return Connection Size
Maximum Fuel Lift: m (ft)
Recommended Fuel
Total Fuel Flow: L/hr (gal/hr)
#16 JIC 37° Female
1” NPT Adapter Provided
#16 JIC 37° Female
1” NPT Adapter Provided
1 (3)
Diesel #2
1,620 (428)
* Air density = 1.184 kg/m (0.0739 lbm/ft3)
//  Exhaust System
Gas Temp. (Stack): °C (°F)
Gas Volume at Stack
Temp: m3/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H20)
STANDBY
784 (207)
594 (157)
413 (109)
STANDBY
47 (117)
0.12 (0.5)
1,567 (414)
567 (150)
1,300 (73,929)
970 (55,162)
230 (13,080)
60.6 (81.3)
STANDBY
264 (9,323)
3,082 (108,843)
888 (31,359)
STANDBY
525 (977)
702 (24,791)
8.5 (34.1)