MA120GQ-Z Datasheet, PDF (13/14 Pages) MPS Industries, Inc. – Angular Sensor for 3-Phase Brushless Motor Commutation
MA120
Angular Sensor for 3-Phase Brushless Motor
Commutation
13. Ordering Information
Part Number
Package
Free Air Temperature (TA)
MA120GQ
QFN 3x3mm
-40° to 125°
* For Tape & Reel, add suffix –Z (e.g. MA120GQ–Z).
Appendix A: Definitions
Resolution (3 noise level)
Refresh rate
The smallest angle increment distinguishable from the noise. Here the resolution
is defined as 3 times , the standard deviation in degrees, taken over 1000 data
points at a constant position. The resolution in bits is obtained with:
6.
Rate at which new data points are stored in the output buffer.
Latency
The time between the data ready at the output and the instant at which the shaft
passes that position. The lag in degrees is
, where is the
angular velocity in deg/s.
Power up time
Starting at power up, time until the sensor delivers valid data.
Integral Non-Linearity (INL)
Maximum deviation between the sensor output and the best line fit.
Monolithic Power Systems, Inc. | Gland, Switzerland | Tel: +41 22 364 63 50 | euroinfo@monolithicpower.com | www.sensimatech.com
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2014 Monolithic Power Systems. All Rights
Reserved. MA700 Rev 1.0 September 2014