HPU100 SERIES
100W Desk top type medical power supplies for Home health care applications.
Description:
The HPU100 series of AC/DC switching mode power supplies
provide 100 Watts of continuous output power . All supplies are
UL94V-1 min compliant, include IEC-320-C14 input for worldwide
applications. They are suited for use in Home health care
applications. All models meet FCC Part-18 Calss B and CISPR-11
EN55011 class B emission Limits and are designed to comply with
UL/c-UL(UL 60601-1) ,TUV/T-mark (EN 60601-1) and new CE
requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 260 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Output Voltage Available From 11VDC Thru 48VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Output Voltage Protection
Active Power Factor Correction
Class I
2 year warranty
Safety Approvals :
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
fin Input Frequency
Operating Voltage
90
260 VAC
47
63 Hz
PF Power Factor Correction
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Io=Full load, Vin=230 VAC
Vin=90 to 260 VAC
0.95
1
0
100 W
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current ( High Line)
I rl Low Line Inrush Current
Io=Full load, Vin=115 VAC
Io=Full load, Vin=230 VAC
Io=Full load, 25 C ,Cool start,
Vin= 115VAC
1.35 A
0.5 A
44 50
A
I rh High Line Inrush Current
Eff Efficiency
Io=Full load, 25 C ,Cool start,
Vin= 230VAC
Io=Full Load, Vin=230VAC
85 100 A
85 87 90 %
REG-i
REG -o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
TC
Line Regulation
Io=Full Load
0.5 1
Load Regulation
Vin=230VAC
3
5
Over Voltage Protection
112
132
Over Current Protection
110
150
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
Hold-Up Time
Io=Full Load, Vin=110VAC
12
Start Up Time
Io=Full Load, Vi n= 10 0V AC
0.3 1.5 2
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
Safety Ground Leakage C urrent Io = Fu ll Load, V i n = 240 V A C/60Hz
0.15 0.25
Temperature Coefficient
All output
-0.04
0.04
%
%
%
%
mS
mS
S
%
mA
%/ C
Environmental :
Sym.
Toper
Tstg
Hr
MTBF
Pd
Parameter
Test Conditions
Operating Temperature
Storage Temperature
Relative Humidity
Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max.
0
70
-40
85
5
95
0.1M
Unit
C
C
%