English
Language : 

MR0611S Datasheet, PDF (2/4 Pages) MicroPower Direct, LLC – Ultra-Wide Input, 6W Miniature, Railway DC/DC Converters
Model Selection Guide
www.micropowerdirect.com
Model
Number
Input
Output
Voltage (VDC)
Nominal Range
Current (mA)
Voltage Current
Full-Load No-Load (VDC) (mA, Max)
Current
(mA, Min)
Efficiency
(%, Typ)
Over
Voltage
Protection
(VDC Typ)
Capacitive
Load
(µF, Max)
Fuse
Rating
Slow-Blow
(mA)
MR0611S-05RU
110
40 - 160
67
MR0611S-12RU
110
40 - 160
65
MB0611S-15RU
110
40 - 160
64
MB0611S-24RU
110
40 - 160
64
2
5.0
1,200
2
12.0
500
2
15.0
400
2
24.0
250
60
81
25
83
20
85
13
85
6.2
1,000
150
15.0
100
150
18.0
100
150
28.8
47
150
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 10 µF) be placed from the +VOUT to
the -VOUT pins.
2. Transient recovery is measured to within a 1% error band for a load step change of 25%.
3. Short circuit protection is provided by a “hiccup mode” circuit.
4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum control current to the on/off
pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/off pin is left open, the unit operates. If it is grounded, the unit will shut off.
5. These units should not be operated with a load under 5% of full load. Operation at no-load will not damage the unit, but they may
not meet all specifications.
6. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the
correct rating.
Efficiency vs Input Voltage (Full Load)
Derating Curve
Efficiency vs Output Power (VIN= 110 VDC)
Mechanical Dimensions
Pin Connections
Pin
Function
1
-VIN
2
+VIN
3
+VOUT
4
-VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)