English
Language : 

MR0611S Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – Ultra-Wide Input, 6W Miniature, Railway DC/DC Converters
MR0611S Series
Ultra-Wide Input, 6W
Miniature, Railway
DC/DC Converters
Electrical Specifications
Key Features:
• 6W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min. Typ. Max. Units
• 40 - 160 VDC Input Range Input Voltage Range
40.0 110.0 160.0 VDC
• Meets EN 60950, EN 50155 Input Start Voltage
40.0
VDC
• Miniature 1 x 1 Inch Case Input Filter
␲ (Pi) Filter
• 1,500 VDC Isolation
• Efficiency to 85%
• -40°C to +85°C Operation
• Industry Standard Pin-Out
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Conditions
Min.
VIN = Min to Max
IOUT = 5% to 100%
Typ.
±1.0
±0.2
±0.5
Max.
±2.0
±0.5
±1.0
Units
%
%
%
Ripple (20 MHz)
See Note 1
10
20 mV P - P
Noise (20 MHz)
See Note 1
70 100 mV P - P
Transient Recovery Time, See Note 2
Transient Response Deviation
25% Load Step Change
300 1,000
µS
±3.0 ±5.0
%
Output Power Protection
110 120 140
%
Temperature Coefficient
±0.03
%/°C
Output Short Circuit, See Note 3
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
M
Isolation Capacitance
100 kHz/0.1V
1,000
pF
Switching Frequency
300
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
See Mechanical Diagram (Page 2)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.77 Oz (22g)
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Units
MHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Vibration, 5 - 150 Hz
Absolute Maximum Ratings
Parameter
Displacement Range
Acceleration
7.5 mm
2G
Conditions
Min. Typ. Max. Units
Input Voltage Surge (1 Sec)
-0.7
200.0 VDC
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com