Model Selection Guide
www.micropowerdirect.com
Model
Number
Input
Voltage (VDC)
Nominal Range
Current (mA)
Voltage
Full-Load No-Load (VDC)
MB1012S-03ERW 12
9.0 - 18.0
857
25
3.3
MB1012S-05ERW 12
9.0 - 18.0 1,016
25
5.0
MB1012S-12ERW 12
9.0 - 18.0
969
25
12.0
MB1012S-15ERW 12
9.0 - 18.0
958
25
15.0
MB1012S-24ERW 12
9.0 - 18.0
947
25
24.0
MB1012D-05ERW 12
9.0 - 18.0 1,016
25
±5.0
MB1012D-12ERW 12
9.0 - 18.0
969
25 ±12.0
MB1012D-15ERW 12
9.0 - 18.0
958
25 ±15.0
MB1012D-24ERW 12
9.0 - 18.0
958
25 ±24.0
MB1024S-03ERW 24 18.0 - 36.0 429
12
3.3
MB1024S-05ERW 24 18.0 - 36.0 496
12
5.0
MB1024S-12ERW 24 18.0 - 36.0 473
12
12.0
MB1024S-15ERW 24 18.0 - 36.0 463
12
15.0
MB1024S-24ERW 24 18.0 - 36.0 479
12
24.0
MB1024D-05ERW 24 18.0 - 36.0 502
12
±5.0
MB1024D-12ERW 24 18.0 - 36.0 484
12 ±12.0
MB1024D-15ERW 24 18.0 - 36.0 473
12 ±15.0
MB1024D-24ERW 24 18.0 - 36.0 479
12 ±24.0
MB1048S-03ERW 48 36.0 - 75.0 212
6
3.3
MB1048S-05ERW 48 36.0 - 75.0 254
6
5.0
MB1048S-12ERW 48 36.0 - 75.0 237
6
12.0
MB1048S-15ERW 48 36.0 - 75.0 234
6
15.0
MB1048S-24ERW 48 36.0 - 75.0 237
6
24.0
MB1048D-05ERW 48 36.0 - 75.0 251
6
±5.0
MB1048D-12ERW 48 36.0 - 75.0 237
6
±12.0
MB1048D-15ERW 48 36.0 - 75.0 234
6
±15.0
MB1048D-24ERW 48 36.0 - 75.0 237
6
±24.0
Output
Current
(mA, Max)
2,400
2,000
833
667
416
±1,000
±416
±333
±208
2,400
2,000
833
667
416
±1,000
±416
±333
±208
2,400
2,000
833
667
416
±1,000
±416
±333
±208
Current
(mA, Min)
120
100
42
33
21
±50
±21
±16
±10
120
100
42
33
21
±50
±21
±16
±10
120
100
42
33
21
±50
±21
±16
±10
Reflected
Ripple
Current
(mA Typ)
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
Capacitive
Load
(µF, Max)
2,200
2,200
470
220
100
±680
±220
±100
±47
2,200
2,200
680
330
100
±680
±330
±220
±100
2,200
2,200
820
470
220
±680
±470
±220
±100
Efficiency
(%, Typ)
77
82
86
87
88
82
86
87
87
77
84
88
90
87
83
86
88
87
78
82
88
89
88
83
88
89
88
Fuse
Rating
Slow-Blow
(mA)
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
500
500
Notes:
1. Cross regulation is measured with the output being tested at 50% load. The second output is varied from 10% to 100%
load.
2. When measuring output ripple, it is recommended that an external ceramic capacitor (approx
10 µF) be placed from the +VOUT to the -VOUT pins for single output models; or from each output to common for dual
output models.
3. Transient recovery is measured to within a 1% error band for a load step change of 25%.
4. Short circuit protection is provided by a “hiccup mode” circuit.
5. These units should not be operated with a load under 5% of full load. Operation at no-load will not damage the unit, but
they may not meet all specifications.
6. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above
for the correct rating.
Derating Curve
Adapter Plate
All models of the MB1000x-xxERW series are available mounted on an adapter
plate similar to the one pictured above. The adapter plate will allow the user to easily
mount the unit to a chassis or to a standard DIN rail. Please contact the factory for
more information.
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com