MB1000ERW Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – MB1000ERW | |||
|
MB1000ERW
Low Cost, 1 x 2 Inch
10W, 2:1 Input Range
DC/DC Converters
Electrical Speciï¬cations
Key Features:
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
⢠10W Output Power
⢠2:1 Input Voltage Range
Parameter
Input Voltage Range
Conditions
Min. Typ. Max.
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
Units
VDC
⢠1,500 VDC Isolation
48 VDC Input 36.0 48.0 75.0
⢠Single & Dual Outputs
⢠Efï¬ciency to 90%
Input Start Voltage
12 VDC Input
24 VDC Input
48 VDC Input
9.0
18.0
VDC
36.0
⢠Compact 1 x 2 Inch Case Input Filter
Output
⢠-40°C to +85°C Operation Parameter
Conditions
â² (Pi) Filter
Min. Typ. Max.
Units
⢠Industry Standard Pin-Out Output Voltage Accuracy
⢠Low Cost
Output Voltage Balance
Line Regulation
Dual Outputs, Balanced Loads
VIN = Min to Max
±1.0 ±2.0
%
±0.5 ±1.5
%
±0.2 ±0.5
%
Load Regulation
IOUT = 5% to 100%
±0.5 ±1.0
%
Cross Regulation
See Note 1
±5.0
%
Ripple (20 MHz)
Noise (20 MHz)
See Note 2
15
40
35
80
mV P - P
Transient Recovery Time, See Note 3
Transient Response Deviation
25% Load Step Change
300 500
±3.0 ±5.0
µSec
%
Temperature Coefï¬cient
±0.03 %/°C
Over Voltage Protection
110 120 140
%
Output Short Circuit, See Note 4
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
Mï
Isolation Capacitance
100 kHz, 0.1V
1,000
pF
Switching Frequency
350
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+105
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
2.0 x 1.0 x 0.465 Inches (50.8 x 25.4 x 11.8 mm)
Case Material
Aluminum Alloy With Non-Conductive Base (UL94-V0)
Weight
0.78 Oz (22g)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Remote On/Off
Parameter
Unit On
Unit Off
Off Idle Current
Reliability Speciï¬cations
Conditions
Min. Typ. Max.
See Note 5 3.5
12.0
See Note 5 0
1.2
1.0 3.0
Units
VDC
VDC
mA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Conditions
Min. Typ. Max.
12 VDC Input -0.7
25.0
Units
MHours
Units
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |