Model Selection Guide
Model
Number
H101E
H102E
H103E
H104E
H105E
H111E
H112E
H113E
H114E
H115E
H121E
H122E
H123E
H124E
H125E
H151E
H152E
Input
Voltage (VDC)
Current (mA)
Nominal Range Full-Load No-Load
5
4.5 - 5.5
278
25
5
4.5 - 5.5
286
25
5
4.5 - 5.5
256
25
5
4.5 - 5.5
252
25
5
4.5 - 5.5
251
25
12
10.8 - 13.2
116
16
12
10.8 - 13.2
118
16
12
10.8 - 13.2
109
16
12
10.8 - 13.2
106
16
12
10.8 - 13.2
105
16
24
21.6 - 26.4
56
8
24
21.6 - 26.4
57
8
24
21.6 - 26.4
53
8
24
21.6 - 26.4
53
8
24
21.6 - 26.4
53
8
3.3
3.0 - 3.6
421
55
3.3
3.0 - 3.6
410
55
Voltage
(VDC)
3.3
5.0
9.0
12.0
15.0
3.3
5.0
9.0
12.0
15.0
3.3
5.0
9.0
12.0
15.0
3.3
5.0
Output
Current
(mA, Max)
303.0
200.0
111.0
83.0
67.0
303.0
200.0
111.0
83.0
67.0
303.0
200.0
111.0
83.0
67.0
303.0
200.0
Current
(mA, Min)
30.0
20.0
12.0
9.5
7.0
30.0
20.0
12.0
9.0
7.0
30.0
20.0
12.0
9.0
7.0
30.0
20.0
Load
Regulation
(%, Max)
20
15
10
10
10
20
15
10
10
10
20
15
10
10
10
20
20
Efï¬ciency
(%, Typ)
72
70
78
79
80
72
71
76
78
80
74
73
78
79
80
72
74
Notes:
1. Output load regulation is speciï¬ed for a load change of 10% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin.
3. During operation, care must be taken not to exceed the speciï¬ed input range
of the unit or to allow the output load to drop below the speciï¬ed minimum
(10% of full load). Operating the unit under either of these conditions could
cause damage to the unit.
4. These converters are speciï¬ed for operation without external components.
However, in some applications the addition of input/output capacitors will
enhance stability and reduce output ripple. Recommended capacitor values
are:
Vin
3.3 VDC
5 VDC
12 VDC
24 VDC
Input
Capacitor
4.7 µF
4.7 µF
2.2 µF
1.0 µF
Vout
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
Output
Capacitor
10.0 µF
10.0 µF
4.7 µF
2.2 µF
1.0 µF
Derating Curve
For applications requiring very low output noise levels, a
simple LC ï¬lter should be effective.
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the table above for the correct rating.
Mechanical Dimensions
Fuse Rating
Slow-Blow
(mA)
500
500
500
500
500
200
200
200
200
200
100
100
100
100
100
750
750
Pin Connections
Pin Function
1
-Vin
4
+Vin
5
+Vout
7
-Vout
Notes:
⢠All dimensions are typical in inches (mm)
⢠Tolerance x.xx = ±0.01 (±0.25)
⢠Pin 1 is marked by a âdotâ or indentation on the
top of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 ⢠TEL: (781) 344-8226 ⢠FAX: (781) 344-8481 ⢠E-Mail: sales@micropowerdirect.com
|