English
Language : 

E200E Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – Low Cost, 2W Ultra-Miniature SIP DC/DC Converters
Model Selection Guide
Model
Number
E201E
E202E
E203E
E211E
E212E
E213E
Input
Output
Voltage (VDC)
Current (mA) Voltage Current Current
Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min)
5
4.5 - 5.5
513
38
5.0
400.0
40.0
5
4.5 - 5.5
506
38
12.0
167.0
17.0
5
4.5 - 5.5
506
38
15.0
133.0
14.0
12 10.8 - 13.2 214
20
5.0
400.0
40.0
12 10.8 - 13.2 208
20
12.0
167.0
17.0
12 10.8 - 13.2 206
20
15.0
133.0
14.0
Load
Regulation
(% Max)
15
15
15
15
15
15
Efficiency
(%, Typ)
78
79
79
78
80
81
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
500
500
500
Notes:
1. Output load regulation is specified for a load change
of 10% to 100%.
2. When measuring output ripple, it is recommended
that an external 0.33 µF ceramic capacitor be placed
from the +Vout pin to the -Vout pin.
3. These units should not be operated with a load under
10% of full load. Operation at no-load may cause
damage to the unit.
4. These converters are specified for operation without
external components. However, in some applications
the addition of input/ouput capacitors will enhance
stability and reduce output ripple. Recommended
capacitor values are:
Derating Curve
Vin
5 VDC
12 VDC
Input
Capacitor
4.7 µF
2.2 µF
Vout
5 VDC
12 VDC
15 VDC
Output
Capacitor
10.0 µF
2.2 µF
1.0 µF
For applications requiring very low output noise
levels, a simple LC filter should be effective.
5. It is recommended that a fuse be used on the input
of a power supply for protection. See the Model
Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin Description
1
-Vin
2
+Vin
3
-Vout
4
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on
the side of the unit
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com