English
Language : 

D200RU Datasheet, PDF (2/2 Pages) MicroPower Direct, LLC – Miniature SIP, 2W Ultra-Wide 4:1 Input DC/DC Converters
Model Selection Guide
Model
Number
D201RU
D202RU
D203RU
D204RU
D205RU
D206RU
D207RU
D211RU
D212RU
D213RU
D214RU
D215RU
D216RU
D217RU
Input
Voltage (VDC)
Current (mA)
Nominal Range Full-Load No-Load
24 9.0 - 36.0
97
20
24 9.0 - 36.0 110
20
24 9.0 - 36.0 106
20
24 9.0 - 36.0 105
20
24 9.0 - 36.0 114
20
24 9.0 - 36.0 108
20
24 9.0 - 36.0 106
20
48 18.0 - 75.0 49
15
48 18.0 - 75.0 58
15
48 18.0 - 75.0 54
15
48 18.0 - 75.0 54
15
48 18.0 - 75.0 60
15
48 18.0 - 75.0 55
15
48 18.0 - 75.0 55
15
Output
Reflected
Voltage Current Current
Ripple
(VDC) (mA, Max) (mA, Min) Current (mA)
3.3
500.0
125.0
300
5.0
400.0
100.0
300
12.0
167.0
42.0
300
15.0
134.0
33.0
300
±5.0 ±200.0
±50.0
300
±12.0 ±83.0
±21.0
300
±15.0 ±67.0
±17.0
300
3.3
500.0
125.0
600
5.0
400.0
100.0
600
12.0
167.0
42.0
600
15.0
134.0
33.0
600
±5.0 ±200.0
±50.0
600
±12.0 ±83.0
±21.0
600
±15.0 ±67.0
±17.0
600
Efficiency
(%, Typ)
71
76
79
80
73
77
79
70
72
78
78
70
76
76
Fuse Rating
Slow-Blow
(mA)
350
350
350
350
350
350
350
135
135
135
135
135
135
135
Notes:
Derating Curve
1. When measuring output ripple, it is recommended that an external
0.47 μF ceramic capacitor be placed from the +Vout pin to the
-Vout pin for single output units and from each output to common
for dual output units. For noise sensitive applications, the use of
3.3 μF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a
load step change of 75% to 100%.
3. Operation at no-load will not damage these units. However, they
may not meet all specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC,
or 30 VDC output. To do this, connect the load across the positive
(+Vout) and negative (-Vout) outputs and float the output com-
mon.
5. The converter should be connected to a low ac-impedance source.
An input source with a highly inductive impedance may affect
the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines,
it may be necessary to use a capacitor on the input to insure start-
up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100
kHz) capacitor be mounted close to the converter. For all models,
it is recommended a 1.5 μF be used.
6. The optional remote
on/off control pin
is referenced to
On
Min
Max
<0.6 VDC to Open Circuit Mechanical Dimensions
the
-Vin pin.
Off
The standby input
current is typically
In. Current (on)
0 . 1 m A ( 0 . 2 m a In. Current (off)
2.7 VDC
15.0 VDC
-1 mA
1 mA
maximum).
7. It is recommended that a fuse be used on the input of a power sup-
ply for protection. See the table above for the correct rating.
Capacitive Load
Output (VDC) μF Max
3.3
2,200
5.0
1,000
12.0
170
15.0
110
±5.0
470
±12.0
100
±15.0
47
Note: For dual output
units, Cap load is given for
each output.
Pin Connections
Pin Single Dual
1
-Vin
-Vin
2 +Vin
+Vin
3 Remote ON/OFF
6 +Vout +Vout
7
NC Common
8
NC
NC
9 -Vout -Vout
NF = No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com