|
MB1500ERW Datasheet, PDF (1/4 Pages) MicroPower Direct, LLC – MB1500ERW | |||
|
MB1500ERW
Low Cost, 1 x 2 Inch
15W, 2:1 Input Range
DC/DC Converters
Electrical Speciï¬cations
Key Features:
Speciï¬cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Speciï¬cations subject to change without notice.
Input
⢠15W Output Power
⢠2:1 Input Voltage Range
Parameter
Input Voltage Range
Conditions
Min. Typ. Max.
12 VDC Input 9.0 12.0 18.0
24 VDC Input 18.0 24.0 36.0
Units
VDC
⢠1,500 VDC Isolation
⢠Single & Dual Outputs
Input Start Voltage
48 VDC Input 36.0 48.0 75.0
12 VDC Input
9.0
24 VDC Input
17.8
VDC
⢠Efï¬ciency to 90%
⢠Compact 1 x 2 Inch Case Under Voltage Shutdown
48 VDC Input
12 VDC Input 7.5
24 VDC Input 16.0
35.8
VDC
⢠-40°C to +85°C Operation
48 VDC Input 32.0
⢠Industry Standard Pin-Out
Input Filter
Start-Up Time
⢠Low Cost
Output
â² (Pi) Filter
See Note 1
10
mS
Parameter
Conditions
Min. Typ. Max. Units
Output Voltage Accuracy
±1.0 ±3.0
%
Output Voltage Balance
Dual Outputs, Balanced Loads
±0.5 ±1.0
Output Trim Range
±10
%
Line Regulation
VIN = Min to Max
±0.2 ±0.5
%
Load Regulation
IOUT = 10% to 100%
±0.5 ±1.0
%
Cross Regulation
See Note 2
±5.0
%
Ripple & Noise (20 MHz)
See Note 3
70 100 mV P - P
Output Power Protection
150
%
Temperature Coefï¬cient
±0.02
%/°C
Output Short Circuit, See Note 4
Continuous (Autorecovery)
General
Parameter
Conditions
Min. Typ. Max. Units
Isolation Voltage
60 Seconds 1,500
VDC
Isolation Resistance
500 VDC 1,000
Mï
Isolation Capacitance
See Note 5
1,000
pF
Switching Frequency
300
kHz
Environmental
Parameter
Conditions
Min. Typ. Max. Units
Operating Temperature Range
Ambient -40 +25 +85
°C
Operating Temperature Range
Case
+105
°C
Storage Temperature Range
-55
+125
°C
Cooling
Free Air Convection
Humidity
RH, Non-condensing
95
%
Physical
Case Size
2.0 x 1.0 x 0.465 Inches (50.8 x 25.4 x 11.8 mm)
Case Material
Aluminum Alloy With Non-Conductive Base (UL94-V0)
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Weight
Remote On/Off
Parameter
Unit On
Unit Off
Off Idle Current
Reliability Speciï¬cations
0.99 Oz (28g)
Conditions
Min. Typ. Max.
See Note 6 2.5
12.0
See Note 6 0
1.2
1.0
Units
VDC
VDC
mA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Conditions
Min. Typ. Max.
MIL HDBK 217F, 25°C, Gnd Benign 1.0
Conditions
Min. Typ. Max.
12 VDC Input -0.7
25.0
Units
MHours
Units
Input Voltage Surge (1 Sec)
24 VDC Input -0.7
50.0
VDC
48 VDC Input -0.7
100.0
Lead Temperature
1.5 mm From Case for 10 Sec
300
°C
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
|
▷ |