English
Language : 

MC33186 Datasheet, PDF (4/12 Pages) Motorola, Inc – Automotive H-Bridge Driver
MC33186
Freescale Semiconductor, Inc.
TRUH TABLE
Device State
Input Conditions
DI1
DI2
IN1
IN2
(3)
(3)
1-Forward
L
H
H
L
2-Reverse
L
H
L
H
3-Free Wheeling Low
L
H
L
L
4-Free Wheeling High
L
H
H
H
5-Disable 1
H
X
X
X
6-Disable 2
X
L
X
X
7-IN1 Disconnected
L
H
Z
X
8-IN2 Disconnected
L
H
X
Z
9-DI1 Disconnected
Z
X
X
X
10-DI2 Disconnected
X
Z
X
X
11-Current Limit.active
L
H
X
X
12-Undervoltage (1)
X
X
X
X
13-Over-temperature (2)
X
X
X
X
14-Over-current (2)
X
X
X
X
Status
SF
SF
(5)
(6)
H
H
H
H
H
H
H
H
L
H
L
H
H
H
H
H
L
H
L
H
H
H
L
L
L
L
L
L
OU1
H
L
L
H
Z
Z
H
X
Z
Z
Z
Z
Z
Z
NOTE :
(1) In case of undervoltage, tristate and status-flag are reset automatically.
(2) Whenever over-current or over-temperature is detected, the fault is stored (i.e.status-flag remains low).
The tristate conditions and the status-flag are reset via DI1 (IN1) or DI2 (IN2).
Pinnames in brackets refer to coding pin (COD=Vcc).
(3) If COD = Vcc then DI1 and DI2 are not active.
(4) In case of over-current, the time when the current is greater than 7,8A is lower than 30µs, with a maximum frequency of 1kHz.
(5) COD=nc or GND
(6) COD = VCC
Outputs
OU2
L
H
L
H
Z
Z
X
H
Z
Z
Z
Z
Z
Z
L = Low
H = High
X = High or Low
Z = High impedance (all output stage transistors are switched off ).
MC33186
For More InformMaOtiToOnROOnLAThis Product,
4