Power-On Reset Timer
This timer starts to time out at the end of the soft-start period
if the VDDH and VDDL outputs are in the valid regulation range.
If the timer “times out”, then the open-drain PWROK signal is
released, indicating that “power is ON”.
Supervisory Circuits PWROK and VKAMOK
The 33997 has two voltage monitoring open-drain outputs,
the PWROK and the VKAMOK pins. PWROK is "active high".
This output is pulled low when either of the regulator outputs
(VDDH or VDDL) are below their regulation windows. If both
regulator outputs are above their respective lower thresholds,
and the Power-On Reset Timer has expired, the output driver is
turned off and this pin is at high-impedance state (see
Figure 6).
The VKAMOK signal indicates a severe fault condition on
the keep-alive regulator output VKAM. The VKAM output voltage
is compared to the internal bandgap reference voltage. When
the VKAM falls below the bandgap reference voltage level, the
VKAMOK signal is pulled low.