V62C318256 Datasheet, PDF (4/12 Pages) Mosel Vitelic, Corp – 2.7 VOLT 32K X 8 STATIC RAM
MOSEL VITELIC
V62C318256
DC Electrical Characteristics (over all temperature ranges, VCC = 2.7V – 3.6V)
Symbol
VCC
VIL
VIH
IIL
IOL
Parameter
Power Supply Voltage
Input LOW Voltage(1,2)
Input HIGH Voltage(1)
Input Leakage Current
Output Leakage Current
VOL
Output LOW Voltage
VOH
Output HIGH Voltage
Test Conditions
VCC = Max, VIN = 0V to VCC
VCC = Max, CE = VIH, VOUT = 0V to
VCC
VCC = Min, IOL = 2.1mA
VCC = Min, IOH = -1mA
Min.
2.7
-0.3
2.2
-2
-2
—
2.4
Typ. Max. Units
—
3.6
V
—
0.4
V
— VCC+0.3 V
—
2
µA
—
2
µA
—
0.4
V
—
—
V
Symbol Parameter
ICC (read)
ICC (write)
ICC1
ISB
Operating Power Supply Current, CE = VIL, WE = VIH
Output Open, VCC = Max., f = 0
Operating Power Supply Current, CE = VIL, WE = VIL
Output Open, VCC = Max., f = 0
Average Operating Current, CE ≤ VIL Output Open,
VCC = Max., f = fMAX(3)
TTL Standby Current
CE ≥ VIH, VCC = Max.
ISB1
CMOS Standby Current, CE ≥ VCC – 0.2V,
VIN ≥ VCC – 0.2V or VIN ≤ 0.2V, VCC = Max.
Com.(4) Ind.
2
2
Units
mA
20
20
mA
40
40
mA
L
2
3
mA
LL
1
1
L
50
60
µA
LL
15
20
NOTES:
1. These are absolute values with respect to device ground and all overshoots due to system or tester noise are included.
2. VIL (Min.) = -3.0V for pulse width < 20ns.
3. fMAX = 1/tRC.
4. Maximum values.
AC Test Conditions
Key to Switching Waveforms
Input Pulse Levels
Input Rise and Fall Times
Timing Reference Levels
Output Load
0 to 3V
5 ns
1.5V
see below
AC Test Loads and Waveforms
+3V
1103 Ω
I/O Pins
1554 Ω
CL = 30 pF*
WAVEFORM
INPUTS
OUTPUTS
MUST BE
STEADY
WILL BE
STEADY
MAY CHANGE
FROM H TO L
WILL BE
CHANGING
FROM H TO L
MAY CHANGE
FROM L TO H
WILL BE
CHANGING
FROM L TO H
DON'T CARE:
ANY CHANGE
PERMITTED
DOES NOT
APPLY
CHANGING:
STATE
UNKNOWN
CENTER
LINE IS HIGH
IMPEDANCE
“OFF” STATE
* Includes scope and jig capacitance
318256 07
V62C318256 Rev. 1.7 July 2001
4