English
Language : 

F0505XD-1W Datasheet, PDF (3/3 Pages) MORNSUN Science& Technology Ltd. – DUAL/SINGLE OUTPUT DC-DC CONVERTER
OUTLINE DIMENSIONS & PIN CONNECTIONS
MECHANICAL DIMENSIONS
0.50 [0.020]
(Front View)
7.00 [0.276]
4.10 [0.161]
RECOMMENDED FOOTPRINT
DUAL/SINGLE OUTPUT
14
12
8
5 67
∅1.00 [∅ 0.039]
0.50 [0.020]
20.00 [0.787]
2.54 [0.100]
7.62
[0.300]
12
5 67
(Bottom View)
14
8
∅1.00
[0.039] 10.00
0.30 [0.394]
[0.012]
Note: grid 2.54*2.54mm.
TUBE DUTLINE DIMENSIONS
12.50 [0.492]
15.24 [0.600]
FOOTPRINT DETAILS
Pin
Single Dual
1
Vi n
Vi n
2
GND GND
5
0V
0V
6
+Vo +Vo
7
NC
- Vo
Others NC
NC
NC: No connection.
Note:
Unit: mm[inch]
Pin section tolerances: ±0.1mm[±0.039inch]
General tolerances: ±0.25mm[±0.010inch]
10.50 [0.413]
16.50 [0.650]
Note:
Unit :mm[inch]
3.50 [0.138]
General tolerances: ±0.50mm[ ±0.020inch]
L=530mm[20.866inch] Tube Quantity: 25pcs
L=220mm[8.661inch] Tube Quantity: 10pcs
Short tube inner package dimensions: L*W*H= 255*170*80mm
Short tube outer package dimensions(with six inner package boxes):
L*W*H= 375*280*270mm
Long tube inner package dimensions: L*W*H= 580*200*100mm
Long tube outer package dimensions(with two inner package boxes):
L*W*H= 600*215*220mm
Long tube outer package dimensions(with three inner package boxes):
L*W*H= 600*215*325mm
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed, and that will reduce the
life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate standards.
4. Only typical models listed, other models may be different, please contact our technical person for more details.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
E_XD-1W & F_XD-1W A/2-2012 Page 3 of 3