English
Language : 

URA2405LD-20WR3_15 Datasheet, PDF (2/9 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
URA_LD-20WR3 & URB_LD-20WR3 Series
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
24VDC input
3.3V output
5V output
--
799/40
818/45
--
969/40
993/45
Input Current (full load / no-load)
48VDC input
Others
3.3V output
5V output
--
948/6
941/10
--
400/20
409/25
mA
--
485/20
497/25
Others
--
474/5
485/9
Reflected Ripple Current
24VDC input
48VDC input
--
30
--
--
30
--
Input impulse Voltage (1sec. max.)
24VDC input
48VDC input
-0.7
--
50
-0.7
--
100
Starting Voltage
24VDC input
48VDC input
--
--
9
VDC
--
--
18
Under Voltage Shutdown
24VDC input
48VDC input
5.5
6.5
--
14.0
15.5
--
Starting Time
Input Filter
Nominal input& constant resistance load
--
10
--
ms
Pi filter
Module switch on
Ctrl suspended or connected to TTL high level (3.5-12VDC)
Ctrl*
Module switch off
Ctrl pin connected to GND or low level (0-1.2VDC)
Input current when switched off
--
4
7
mA
Hot Plug
Note: *The voltage of Ctrl pin is relative to input pin GND.
Unavailable
Output Specifications
Item
Output Voltage Accuracy①
Balance of Output Voltage
Line Regulation
Load Regulation②
Cross Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Drift Coefficient
Ripple & Noise③
Trim
Over-voltage Protection
Over-current Protection
Short circuit Protection
Operating Conditions
0%-100% load
Dual output, balanced load
Full load, the input voltage is
Positive Output
from low voltage to high voltage Negative Output
5%-100% load
Positive Output
Negative Output
Dual output, main output 50% load,
Supplement output from 10% to 100% load
25% load step change 3.3V/5V/±5V output
Others
Full load
20MHz bandwidth, 5%-100% load
Input voltage range
Min.
Typ.
Max.
Unit
--
±1
±3
--
±0.5
±1.5
--
±0.2
±0.5
--
±0.5
±1
%
--
±0.5
±1
--
±0.5
±1.5
--
--
±5
--
300
500
µs
--
±5
±8
%
--
±3
±5
--
--
±0.03
%/℃
--
50
100
Mv p-p
--
±10
--
110
--
160
%Vo
110
--
190
%Io
Hiccup, Continuous, self-recovery
Note:①At 0%~5% load, the Max. output voltage accuracy of ±5VDC/±9VDC output converter is ±5%.
②When testing from 0% to100%load working conditions,load regulation index of ±5%;
③0%-5% load ripple&Noise is no more than 5%Vo.Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application
Notes for specific operation.
2015.09.28-A/3
Page 2 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation