English
Language : 

URA2405LD-20WR3_15 Datasheet, PDF (1/9 Pages) MORNSUN Science& Technology Ltd. – DC/DC Converter
DC/DC Converter
URA_LD-20WR3 & URB_LD-20WR3 Series
20W,Ultra wide input isolated & regulated dual /
single output DC/DC converter
FEATURES
 Wide range of input voltage (4:1)
 Efficiency up to 90%
 No-load power consumption as low as 0.15W
 Isolation voltage :1500VDC
 Input under-voltage protection, output short
circuit protection, over-voltage protection,
over-current protection
 Operating temperature range: -40℃ to +85℃
 Meet CISPR22/EN55022 CLASS A
 Six-sided metal shielding package
 A2S (wring mounting) and A4S (35mm rail
mounting) products featuring reverse polarity
protection for input
 Meet UL60950 , EN60950 and IEC60950
CB Patent Protection RoHS
URA_LD-20WR3 & URB_LD-20WR3 series are isolated 20W DC-DC products with 4:1 input voltage. They feature efficiency up to 90%, 1500VDC
isolation, operating temperature of -40℃~+85℃, Input under-voltage protection, output short circuit protection, over-voltage protection,
over-current protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in data transmission device, battery
power supplies, tele-comunication device, distributed power supply system, remote control system, industrial robot system fields. And
extension package A2S and A4S also enable them with reverse voltage protection.
Selection Guide
Certification
Part No. ①
Input Voltage (VDC)
Nominal
(Range)
Max. ②
Output
Output Voltage Output Current
(VDC)
(mA)(Max./Min.)
Efficiency③
(%,Min./Typ.)
@ Full Load
Max. Capacitive
Load④(µF)
URA2405LD-20WR3
±5
±2000/0
84/86
4800
URA2409LD-20WR3
±9
±1111/0
86/88
1000
URA2412LD-20WR3
±12
±834/0
86/88
800
URA2415LD-20WR3
±15
±667/0
86/88
625
URB2403LD-20WR3
URB2405LD-20WR3
24
(9-36)
40
3.3
5
5000/0
4000/0
84/86
88/90
10000
10000
URB2409LD-20WR3
9
2222/0
87/89
4700
UL/CE/CB URB2412LD-20WR3
12
1667/0
87/89
1600
URB2415LD-20WR3
15
1333/0
88/90
1000
URB2424LD-20WR3
24
834/0
88/90
500
URA4805LD-20WR3
±5
±2000/0
84/86
4800
URA4812LD-20WR3
±12
±834/0
86/88
800
URA4815LD-20WR3
±15
±667/0
87/89
625
URB4803LD-20WR3
3.3
URB4805LD-20WR3
48
(18-75)
80
5
--
URB4809LD-20WR3
9
5000/0
4000/0
2222/0
84/86
88/90
87/89
10000
10000
4700
URB4812LD-20WR3
12
1667/0
87/89
1600
UL/CE/CB URB4815LD-20WR3
15
1333/0
88/90
1000
URB4824LD-20WR3
24
834/0
88/90
500
Notes:①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URB2405LD-20WHR3A2S is chassis mounting of with heat sink,URB2405LD-20WR3A4S is DIN-Rail mounting of without heat sink; If the application has a
higher requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter, but it isn't recommended;
③Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection,
minimum efficiency greater than Min.-2 is qualified;
④ The capacitive loads of positive and negative outputs are identical.
2015.09.28-A/3
Page 1 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation