English
Language : 

URB2403YMD-20W Datasheet, PDF (1/8 Pages) MORNSUN Science& Technology Ltd. – REGULATED SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
URB_YMD-20W Series
20W,ULTRA WIDE INPUT,ISOLATED &
REGULATED SINGLE OUTPUT DIP
PACKAGING, DC-DC CONVERTER
Patent Protected RoHS
PART NUMBER SYSTEM
URB 2 40 5Y MD-20 W
Rated Power
Package
Output Voltage
Input Voltage
Product Series
FEATURES
●4:1 Ultra wide input voltage range
●Small footprint,20W,1×1inch
●Efficiency up to 90%
●1.5KVDC isolation
●Short circuit protection(automatic recovery)
●Over load protection
●Over temperature protection
●Input under voltage protection
●Output over voltage protection
●Metal shielding package
●Meet CISPR22/EN55022 CLASS A
●Low temperature rise, Industrial level
specifications
●Inverse polarity protection for A2S(chassis
mounting)and A4S(DIN-Rail mounting)
APPLICATION
URB_YMD-20W series are applied to the data transmission
device, battery-powered equipment, communications equipment,
distributed power systems, mixed analog / digital systems, remote
control system, industrial robot system and wide input voltage
occasions.
SELECTION GUIDE
①
Model
Input Voltage(VDC)
Nom inal
(Range)
②
Max
Output
Voltage
(VDC)
Output Current (mA)
Max.
Min.
Input Current
(m A)(Typ.)
@Max.
Load
@No
Load
Reflected
Ripple
Current
(Ma,Typ.)
Max.
Capacitive
Load(µF)
Efficiency
(%, Typ.)
@Max.
③
Load
URB2403YMD-20W
3.3
5000
250
780
50
10300
87
URB2405YMD-20W
URB2412YMD-20W
24
(9-36)
40
5
4000
200
12
1667
84
925
925
60
60
5400
90
1200
90
URB2415YMD-20W
URB4803YMD-20W
15
1333
67
925
60
3.3
5000
250
390
25
750
90
30
10300
88
URB4805YMD-20W
URB4812YMD-20W
48
(18-75)
80
5
4000
200
463
12
1667
84
463
30
30
5400
90
1200
90
URB4815YMD-20W
15
1333
67
463
30
750
90
Note: ① Series with suffix “H” are heat sink mounting, series with suffix "A2S" are chassis mounting, with suffix "A4S" are DIN-Rail mounting, for example
URB2405YMD-20WHA2S is chassis mounting with heat sink, URB2405YMD-20WA4S is DIN-Rail mounting without heat sink. If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink.
②Absolute maximum rating without damage on the converter, but it isn't recommended.
③The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
INPUT SPECIFICATIONS
Item
Test Conditions
24VDC input
Input Surge Voltage (1sec.max.)
48 VDC input
Start-up Voltage
24VDC input
48 VDC input
Under Voltage Shutdown
24VDC input
48 VDC input
Min.
Typ.
Max.
Unit
-0.7
--
50
-0.7
--
100
--
--
9
VDC
--
--
18
6
--
--
15
--
--
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URB_YMD- 20W
2013.05.21-A/2 Page 1 of 8