English
Language : 

PS21964-T Datasheet, PDF (6/10 Pages) Mitsubishi Electric Semiconductor – 600V/15A low-loss 5th generation IGBT inverter bridge for three phase DC-to-AC power conversion
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21964-T/-AT/-CT/-TW
TRANSFER-MOLD TYPE
INSULATED TYPE
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
ID
VFOH
VFOL
VSC(ref)
IIN
OTt
OTrh
UVDBt
UVDBr
UVDt
UVDr
tFO
Vth(on)
Vth(off)
Vth(hys)
Circuit current
Fault output voltage
Short circuit trip level
Input current
Over temperature protection
(Note 5)
Control supply under-voltage
protection
Fault output pulse width
ON threshold voltage
OFF threshold voltage
ON/OFF threshold hysteresis
voltage
VD = VDB = 15V
VIN = 5V
Total of VP1-VNC, VN1-VNC
VUFB-U, VVFB-V, VWFB-W
VD = VDB = 15V
VIN = 0V
Total of VP1-VNC, VN1-VNC
VUFB-U, VVFB-V, VWFB-W
VSC = 0V, FO terminal pull-up to 5V by 10kΩ
VSC = 1V, IFO = 1mA
Tj = 25°C, VD = 15V
(Note 4)
VIN = 5V
VD = 15V,
At temperature of LVIC
Trip level
Trip/reset hysteresis
Trip level
Tj ≤ 125°C
Reset level
Trip level
Reset level
(Note 6)
Applied between UP, VP, WP, UN, VN, WN-VNC
Limits
Unit
Min. Typ. Max.
—
—
2.80 mA
—
—
0.55 mA
—
—
2.80 mA
—
—
0.55 mA
4.9
—
—
V
—
—
0.95
V
0.43
0.48
0.53
V
0.70
1.00
1.50
mA
100
120
140
°C
—
10
—
10.0
—
12.0
V
10.5
—
12.5
V
10.3
—
12.5
V
10.8
—
13.0
V
20
—
—
µs
—
2.1
2.6
V
0.8
1.3
—
V
0.35
0.65
—
V
Note 4 : Short circuit protection is functioning only for the lower-arms. Please select the external shunt resistance such that the SC trip-level is
less than 1.7 times of the current rating.
5 : Over temperature protection (OT) outputs fault signal, when the LVIC temperature exceeds OT trip temperature level (OTt). In that case
if the heat sink comes off DIP-IPM or fixed loosely, don’t reuse that DIP-IPM. (There is a possibility that junction temperature of power
chips exceeded maximum Tj (150°C)).
6 : Fault signal is asserted only corresponding to a SC, a UV or an OT failure at lower side, and the FO pulse width is different for each fail-
ure modes. For SC failure, FO output is with a fixed width of 20µsec(min), but for UV or OT failure, FO output continuously during the
whole UV or OT period, however, the minimum FO pulse width is 20µsec(min) for very short UV or OT period less than 20µsec.
MECHANICAL CHARACTERISTICS AND RATINGS
Parameter
Condition
Limits
Unit
Min.
Typ.
Max.
Mounting torque
Weight
Heat-sink flatness
Mounting screw : M3
Recommended : 0.69 N·m 0.59
—
0.78 N·m
(Note 7)
—
10
—
g
(Note 8) –50
—
100
µm
Note 7 : Plain washers (ISO 7089~7094) are recommended.
Note 8: Flatness measurement position
+–
Heat sink side
Measurement position
4.6mm
DIP-IPM
–
+
Heat sink side
6