English
Language : 

PS11035 Datasheet, PDF (4/5 Pages) Powerex Power Semiconductors – Intellimod™ Module Application Specific IPM (20 Amperes/600 Volts)
MITSUBISHI SEMICONDUCTOR <Application Specific Intelligent Power Module>
PS11035
FLAT-BASE TYPE
INSULATED TYPE
ELECTRICAL CHARACTERISTICS (Tj = 25°C, VD = 15V, VDB = 15V unless otherwise noted)
Symbol
Item
Condition
Ratings
Min.
Typ.
Max. Unit
ID
Circuit current (Average)
Tj = 25°C, VD = 15V, Vin = 5V
—
—
50
mA
IDB
Vth(on)
Vth(off)
Ri
fPWM
tdead
Circuit current (Average)
Input on threshold voltage
Input off threshold voltage
Input pull-up resistor
PWM input frequency
Arm shoot-through blocking time
tint
Input interlock sensing
Vamp(100%) Inverter DC-Link IGBT current sense voltage
Vamp(200%) output signal
Vamp(250%) Inverter DC-Link IGBT current sense voltage
Vamp(0) output limit
OC
Over current trip level
tOC
Over current delay time
SC
Short circuit trip level
tSC
Short circuit delay time
UVD
Trip level
UVDr
UVDB
UVDBr
Supply circuit under
voltage protection
Reset level
Trip level
Reset level
tdV
Delay time
tFO
Fault output pulse width
IFo(H)
IFo(L)
Fault output current
Tj = 25°C, VD = VDB = 15V, Vin = 5V
—
0.8
2.5
Applied between input terminal-inside power supply —
TC ≤ 100°C, Tj ≤ 125°C
1
Relates to corresponding inputs
2.2
TC = –20°C ~ +100°C
(Note 3)
Relates to corresponding input (Fig. 6) —
IC = IOP(100%)
VD = 15V
1.5
IC = IOP(200%) Tj = 25°C (Fig. 4) 3.0
IC = IOP(250%)
VD = 15V
5.0
IC = 0A
(Fig. 4) —
Tj = 25°C
(Fig. 5) 19.8
Tj = 25°C
(Fig. 5) —
Tj = 25°C
(Fig. 5) —
Tj = 25°C
(Fig. 5) —
11.0
11.5
TC = Tj = 25°C
(Fig. 5) 10.1
10.6
—
Tj = 25°C
(Note 4) 1.0
Open collector output
(Note 4) —
—
—
1.4
3.0
50
—
—
100
2.0
4.0
—
50
24.7
10
40
2
12.0
12.5
10.8
11.3
10
1.8
—
—
5
mA
2.0
V
4.0
V
—
kΩ
15
kHz
—
µs
—
ns
2.5
V
5.0
V
—
V
100 mV
35.0
A
—
µs
—
A
—
µs
13.0
V
13.5
V
11.6
V
12.1
V
—
µs
—
ms
1
µA
15
mA
(Note 3) : The dead-time has to be set externally by the CPU; it is not part of the ASIPM internal functions.
(Note 4) : Fault output signaling is given only when the internal OC, SC, & UV protection circuits are activated.
The OC, SC and UV protection (and fault output) operate for the lower arms only. The OC and SC protection Fault output is given
in a pulse format while that of UV protection is maintained throughout the duration of the under-voltage condition.
RECOMMENDED OPERATING CONDITIONS
Symbol
Item
Condition
Ratings
Min.
Typ.
Max.
VCC
Supply voltage
Applied across P2-N2 terminals
—
300
400
VD
Supply voltage
Applied between VD-GND
13.5 15.0 16.5
VDB
Supply voltage
Applied between CBU+ & CBU–, CBV+ & CBV–, CBW+ & CBW– 13.5 15.0 16.5
∆VD, VDB Supply voltage ripple
–1
—
+1
VCIN(ON) Input on voltage
VCIN(OFF) Input off voltage
Applied between UP • VP • WP • UN • VN • WN and
GND
0
—
0.8
4.0
—
5.0
tdead
Arm shoot-through blocking time Relates to corresponding inputs
2.2
—
—
TC
Module case operating temperature
—
—
100
fPWM
PWM Input frequency
TC ≤ 100°C, Tj ≤ 125°C
—
—
15
tXX
Allowable minimum input on-pulse width
1
—
—
INVERTER DC-LINK IGBT CURRENT ANALOGUE
SIGNALING OUTPUT (TYPICAL)
5
VD = 15V
4
Tj = 25°C
Vamp
Vamp (200%)
3
Unit
V
V
V
V/µs
V
V
µs
°C
kHz
µs
2
Vamp (100%)
1
0
0
100
200
300
Actual Load Peak Current (%), (IC = IO! 2)
(Fig. 4)
Jan. 2000