English
Language : 

AQF-30C Datasheet, PDF (4/7 Pages) Minmax Technology Co., Ltd. – 30 Watts Universal Input Range AC/DC Power Modules
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Inrush Current (Cold Start at 25])
Conditions
All Models
115VAC
230VAC
AQF-30 Series
Min.
Typ.
Max.
Unit
85
---
265
VAC
47
---
440
Hz
---
---
20
A
---
---
40
A
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Cross Regulation-
Dual Positives / Triple Output
Ripple & Noise (20MHz)
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min.
Typ.
Single / Dual Output
---
{1.0
Dual Positive / Triple Output
Vo1
Vo2&Vo3
---
---
{1.0
{3.0
Vin=Min. to Max.
---
{0.2
Single Output Models
---
{0.5
Dual Output Models
Iout=Min. to Max.
Vo1
Triple Output Models
Vo2&Vo3
---
---
---
{2.5
{2.5
{4.0
Vo1
---
{2.0
Vo2
Measured output Io = 20% to 100% of rated load
Other output are set at 50% of rated load
---
{5.0
Vo3
---
{5.0
3.3 & 5.0VDC Output Models
---
1.5
Other Output Models
---
1.0
Zener diode clamp
---
120
--- {0.02
---
---
85VAC, Hiccup technique, auto-recovery
105
---
Hiccup mode, indefinite (automatic recovery)
Max.
{2.0
{2.0
---
{1.0
{1.0
{5.0
{5.0
---
---
---
---
1.8
1.3
---
---
5
---
Unit
%
%
%
%
%
%
%
%
%
%
%
%Vpp of Vo
%Vpp of Vo
% of Vo
%/]
%
%
General Specifications
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Switching Frequency
Hold-up Time
MTBF
Conditions
Input to Output, 60 Seconds
Input to Output, Flash Tested for 1 Second
500VDC
115VAC, 60Hz
MIL-HDBK-217F @ 25], Ground Benign
Min.
3000
4700
100
---
---
250
Typ.
---
---
---
100
20
---
Max.
---
---
---
---
---
---
Unit
VAC
VDC
M[
KHz
ms
K Hours
Input Fuse
Built-in Fuse
External Fuse (Recommended)
All Models
3.5A / 250VAC
1.5A Slow - Blow Type
REV:14 2008/08
MINMAX
4