English
Language : 

AQF-30C Datasheet, PDF (3/7 Pages) Minmax Technology Co., Ltd. – 30 Watts Universal Input Range AC/DC Power Modules
AQF-30 Series
Environmental Specifications
Note:
Parameter
Operating Temperature
Storage Temperature
Humidity
Cooling
Conducted EMI
Conducted EMC
Conditions
Ambient
Min.
Max.
-25
71
-40
85
---
95
Free-Air Convection
EN55022 Class B
Standard
specification
requirement
EN61000-4-2
Air {8KV
Cont. {4KV
Unit
]
]
%
Performance
Criteria
B
80~1000MHz 10V/m
EN61000-4-3
80% AM1KHz
A
modulation
AC port {2KV
EN61000-4-4 DC, SL, TL {2KV
B
not less than 1 min.
1.2/50uS(8/20uS)
EN61000-4-5
AC dif. {1KV
B
DC {0.5KV
0.15~80MHz 10Vrms
(functional earth ports
EN61000-4-6
included)
B
80% AM 1kHz
modulation
1. Specifications typical at Ta=+25], resistive
load, 115VAC, 60Hz input voltage, rated output
current unless otherwise noted.
2. Ripple & Noise measurement bandwidth is
0~20 MHz.
3. These power modules require a minimum
output loading to maintain specified regulation.
4. Operation under no-load conditions will not
damage these devices; however they may not
meet all listed specifications.
5. Other input and output voltage may be
available, please contact factory.
6. Specifications subject to change without
notice.
7. Peak current can’ t be drawn from all output at
the same time.
8. Floating (or isolated) output of a power supply
that is not connected to any other output.
9. To order the power module with chassis
mounting style, please add a suffix C (e.g.
AQF-30S05C).
10. Part Number for DIN-Rail bracket:
AC-DIN-02
30% 10ms
B
EN61000-4-11
60% 100ms
C
95% 5000ms
C
3
MINMAX
REV:14 2008/08