English
Language : 

MJWI10_15 Datasheet, PDF (2/5 Pages) Minmax Technology Co., Ltd. – DC/DC CONVERTER 10W, High Power Density
®
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (on)
Control Input Current (off)
Control Common
Standby Input Current
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF(calculated)
Safety Approvals
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
RFI
Lead Temperature (1.5mm from case for 10Sec.)
MJWI10 SERIES
DC/DC CONVERTER 10W, High Power Density
Conditions
Min.
Typ.
Max.
Unit
2.5V ~ 50V or Open Circuit
0~1.0V or Short Circuit (Pin 2 and Pin 6)
Vctrl = 5V
---
---
500
μA
Vctrl = 0V
---
---
-500
μA
Referenced to Negative Input
---
---
10
mA
Conditions
Min.
Typ.
---
---
Dual Output, Balanced Loads
---
±1.0
Vin=Min. to Max. @Full Load
---
±0.3
Io=15% to 100%
---
±0.5
0-20 MHz Bandwidth
---
---
25% Load Step Change
---
300
---
±3
---
±0.01
Hiccup
110
150
Hiccup Mode, Automatic Recovery
Max.
±2.0
±2.0
±1.0
---
100
600
±6
±0.02
---
Unit
%Vnom.
%
%
%
mV p-p
μsec
%
%/℃
%
Conditions
Min.
Typ.
Max.
60 Seconds
1500
---
---
1 Second
1800
---
---
500 VDC
1000
---
---
100KHz, 1V
---
---
1500
---
450
---
MIL-HDBK-217F@25℃, Ground Benign
350,000
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
Unit
VDC
VDC
MΩ
pF
KHz
Hours
Conditions
Min.
Max.
Natural Convection
-40
+80
---
+100
-50
+125
---
95
Natural Convection
Six-Sided Shielded, Metal Case
---
260
Unit
℃
℃
℃
% rel. H
℃
E-mail:sales@minmax.com.tw Tel:886-6-2923150