English
Language : 

APT50GP60LDL Datasheet, PDF (5/9 Pages) Microsemi Corporation – Resonant Mode Combi IGBT
TYPICAL PERFORMANCE CURVES
10,000
Cies
1,000
500
Coes
100
50
Cres
10
0
10
20
30
40
50
VCE, COLLECTOR-TO-EMITTER VOLTAGE (VOLTS)
Figure 17, Capacitance vs Collector-To-Emitter Voltage
APT50GP60LDL(G)
200
180
160
140
120
100
80
60
40
20
0
0 100 200 300 400 500 600 700
VCE, COLLECTOR TO EMITTER VOLTAGE
Figure 18,Minimim Switching Safe Operating Area
0.20
D = 0.9
0.16
0.7
0.12
0.08
0.04
0
10-5
0.5
Note:
0.3
t1
0.1
0.05
SINGLE PULSE
t2
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
10-4
10-3
10-2
10-1
1.0
RECTANGULAR PULSE DURATION (SECONDS)
Figure 19a, Maximum Effective Transient Thermal Impedance, Junction-To-Case vs Pulse Duration
Junction
temp. (°C)
Power
(watts)
RC MODEL
0.00908
0.0193
0.0658
0.00463
0.00218
0.0142
.01.0065558
.03.401642
Case temperature. (°C)
FIGURE 19b, TRANSIENT THERMAL IMPEDANCE MODEL
220
100
50
F
max
=
min
(fmax,
f
max2)
0.05
fmax1 = t d(on) + tr + td(off) + tf
TJ = 125°C
TC = 75°C
D = 50 %
VCE = 667V
10 RG = 5Ω
fmax2 =
Pdiss - P cond
E on2 + E off
Pdiss =
TJ - T C
R θJC
10 20 30 40 50 60 70 80 90 100
IC, COLLECTOR CURRENT (A)
Figure 20, Operating Frequency vs Collector Current