9.1.4 WRITE TO USER EEPROM COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C â¤TA â¤+70°C
Industrial (I):
-40°C â¤TA â¤+85°C
Symbol
Parameters
Min.
Typ.
Max.
Units
TWR Write command activation time
20
â
1000
μs
TACK EEPROM write acknowledge time
â
TRESP Microcontroller acknowledge
response time
20
â
10
ms
â
1000
μs
TACK2
Decoder response
acknowledge time
â
â
10
μs
Note: These parameters are characterized but not tested.
9.1.5 ERASE ALL COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C â¤TA â¤+70°C
Industrial (I):
-40°C â¤TA â¤+85°C
Symbol
Parameters
Min.
Typ.
Max.
Units
TERA Learn command activation time
20
TACK Decoder acknowledge time
20
TRESP
Microcontroller acknowledge
response time
20
TACK2 Decoder data line low
â
Note: These parameters are characterized but not tested.
â
1000
μs
â
210
ms
â
1000
μs
â
10
μs
9.1.6 ACTIVATE LEARN COMMAND IN MICRO MODE
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C â¤TA â¤+70 °C
Industrial (I):
-40°C â¤TA â¤+85°C
Symbol
Parameters
Min.
Typ.
Max.
Units
TLRN Learn command activation time
20
â
1000
μs
TACK Decoder acknowledge time
â
â
20
μs
TRESP
Microcontroller acknowledge
response time
20
â
1000
μs
TACK2 Decoder data line low
â
â
10
μs
Note: These parameters are characterized but not tested.
9.1.7 ACTIVATE LEARN COMMAND IN STAND-ALONE MODE
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C â¤TA â¤+70°C
Industrial (I):
-40°C â¤TA â¤+85°C
Symbol
Parameters
Min.
Typ.
Max.
Units
TREQ Command request time
â
â
100
ms
TLRN Learn command activation time
â
â
2
s
TERA Erase-all command activation time
â
â
6
s
Note: These parameters are characterized but not tested.
DS40183E-page 26
© 2011 Microchip Technology Inc.
|
▷ |