English
Language : 

SST39LF200A_11 Datasheet, PDF (10/37 Pages) Microchip Technology – Mbit / 4 Mbit / 8 Mbit (x16) Multi-Purpose Flash
A Microchip Technology Company
2 Mbit / 4 Mbit / 8 Mbit Multi-Purpose Flash
SST39LF200A / SST39LF400A / SST39LF800A
SST39VF200A / SST39VF400A / SST39VF800A
Data Sheet
Product Identification Mode Exit/CFI Mode Exit
In order to return to the standard Read mode, the Software Product Identification mode must be exited.
Exit is accomplished by issuing the Software ID Exit command sequence, which returns the device to
the Read mode. This command may also be used to reset the device to the Read mode after any inad-
vertent transient condition that apparently causes the device to behave abnormally, e.g., not read cor-
rectly. Please note that the Software ID Exit/CFI Exit command is ignored during an internal Program
or Erase operation. See Table 4 for software command codes, Figure 15 for timing waveform, and Fig-
ure 20 for a flowchart.
Operations
Table 3: Operation Modes Selection
Mode
Read
Program
Erase
CE#
VIL
VIL
VIL
OE#
VIL
VIH
VIH
WE#
VIH
VIL
VIL
DQ
DOUT
DIN
X1
Standby
Write Inhibit
Product Identification
Software Mode
VIH
X
X
VIL
X
X
VIL
VIL
1. X can be VIL or VIH, but no other value.
X High Z
X High Z/ DOUT
VIH High Z/ DOUT
VIH
Address
AIN
AIN
Sector or Block address,
XXH for Chip-Erase
X
X
X
See Table 4
T3.4 25001
Table 4: Software Command Sequence
Command
Sequence
1st Bus
2nd Bus
3rd Bus
4th Bus
5th Bus
6th Bus
Write Cycle Write Cycle Write Cycle Write Cycle Write Cycle Write Cycle
Word-Program
Sector-Erase
Block-Erase
Chip-Erase
Addr
1
5555H
5555H
5555H
5555H
Data
2
AAH
AAH
AAH
AAH
Addr1
2AAAH
2AAAH
2AAAH
2AAAH
Data
2
55H
55H
55H
55H
Addr
1
5555H
5555H
5555H
5555H
Data
2
A0H
80H
80H
80H
Addr
1
WA3
5555H
5555H
5555H
Data
2
Data
AAH
AAH
AAH
Addr1
2AAAH
2AAAH
2AAAH
Data
2
55H
55H
55H
Addr
1
SAX4
BAX4
5555H
Data
2
30H
50H
10H
Software ID
Entry5,6
5555H AAH 2AAAH 55H 5555H 90H
CFI Query Entry5 5555H AAH 2AAAH 55H 5555H 98H
Software ID Exit7/ XXH F0H
CFI Exit
Software ID Exit7/ 5555H AAH 2AAAH 55H 5555H F0H
CFI Exit
T4.3 25001
1. Address format A14-A0 (Hex), Addresses AMS-A15 can be VIL or VIH, but no other value, for the Command sequence.
AMS = Most significant address
AMS = A16 for SST39LF/VF200A, A17 for SST39LF/VF400A, and A18 for SST39LF/VF800A
2. DQ15-DQ8 can be VIL or VIH, but no other value, for the Command sequence
3. WA = Program word address
©2011 Silicon Storage Technology, Inc.
10
DS25001A
03/11