English
Language : 

MIC3001 Datasheet, PDF (61/74 Pages) Micrel Semiconductor – SFP Management IC with Internal Calibration
MIC3001
Bit
D[7]
D[6]
ADSTP
D[5]
ADIDL
D[4]
1SHOT
D[3]
ADSPIN
D[2], D[1], SPIN[2:0]
D[0]
Micrel
Function
Operation
Reserved
Always write as zero; reads undefined.
Stop ADC Halts the analog to digital converter 0 = normal operation; 1 = stopped; Read/write.
ADC idle flag
0 = busy; 1 = idle; Read/write.
Triggers one-shot A/D conversion cycle
0 = normal operation; 1 = one-shot; Read/write.
Selects ADC spin-on-channel mode; do not
enable ADC and FC spin-on-channel modes
simultaneously
0 = normal operation; 1 = spin-on-channel;
Read/write.
ADC and fault comparator (FC) channel select for ADC: 000 = temperature; 001 = voltage; 010 = VILD;
spin-on-channel mode; do not enable ADC and 011 = VMPD; 100 = VRX; FC: 001 = VILD;
FC spin-on-channel modes simultaneously
001 = VMPD; 010 = VRX; Read/write.
Look-Up Table Index (LUTINDX)
Look-up table index as determined by temperature compensation logic
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
D[0]
read/write
Default Value
Serial Address
0000 0000b = 00h
A6h = 1010011b
Byte Address
18 = 12h
The look-up table index is derived from the current temperature measurement and LUTOFF as follows:
INDEX
=

TAVG
2
(µ)
+ LUTOFF
where
TAVG(n)
is
the
current
average
temperature.
This
register
allows
the
current
table
index to be read by the host. The table base address must be added to LUTINDX to form a complete table index in
physical memory. A valid OEM password is required for access to this register. Otherwise, reads are undefined.
OEM Configuration 3 (OEMCFG3)
D[7]
LUTSEL
read/write
D[6]
TXFPOL
read/write
D[5]
GPOD
read/write
D[4]
GPOM
read/write
D[3]
GPOC
read/write
D[2]
TXFIN
read/write
D[1]
LOSDIS
read/write
D[0]
INTCAL
read/write
Default Value
0000 1000b = 08h
Serial Address
A6h = 1010011b
Byte Address
19 = 13h
This register is non-volatile and will be maintained through power and reset cycles. A valid OEM password is required
for access to this register. GPOD and GPOC are ignored when GPOM = 0. TXFPOL is ignored if TXFIN = 0.
Bit
D[7]
LUTSEL
D[6]
TXFPOL
D[5]
GPOD
D[4]
GPOM
D[3]
GPOC
D[2]
TXFIN
D[1]
LOSDIS
D[0]
INTCAL
Function
RX power look-up table input selection bit
TXFIN active polarity select; a fault is indicated
when TXFIN = TXFPOL
GPO output drive
GPO/RSOUT mode select
GPO output control
TXFIN mode select
RXLOS comparator disable
Calibration mode select
Operation
1 = RX power;
0 = temperature; read/write; ignored if INTCAL = 0.
0 = active-low;
1 = active-high; read/write; ignored if TXFIN = 0.
0 = open drain;
1 = push-pull; read/write; ignored if GPOM = 0.
0 = RSOUT; 1 = GPO; read/write.
0 = low; 1 = high; read/write; ignored if GPOM = 0.
0 = SHDN; 1 = TXFIN; read/write.
0 = enabled; 1 = disabled; read/write.
0 = external calibration;
1 = internal calibration; read/write.
August 2004
61
M9999-082404