Electrical Characteristics: at TA = +25°C, VDD = 5V (unless otherwise noted)
Characteristic
Output Leakage Current
Collector-Emitter
Saturation Voltage
Input Voltage
Symbol
ICEX
VCE(SAT)
VIN(0)
VIN(1)
Input Resistance
RIN
Supply Current
Clamp Diode
Leakage Current
Overcurrent Threshold
Start-Up Voltage
Minimum Operating VDD
Clamp Diode Forward Voltage
Thermal Shutdown
Thermal Shutdown Hystersis
IDD(ON)
(One output
active)
IDD(ON)
(All outputs
active)
IDD(OFF)
(Total)
IR
ILIM
VSU
VDD MIN
VF
Test Conditions
VCE = 80V, TA = +25°C
VCE = 80V, TA = +70°C
IC = 100mA
IC = 200mA
IC = 350mA
VDD = 12V
VDD = 10V
VDD = 5.0V (See Note)
VDD = 12V
VDD = 10V
VDD = 5.0V
VDD = 12V, Outputs Open
VDD = 10V, Outputs Open
VDD = 5.0V, Outputs Open
VDD = 12V, Outputs Open
VDD = 10V, Outputs Open
VDD = 5.0V, Outputs Open
VDD = 12V, Outputs Open, Inputs = 0V
VDD = 5.0V, Outputs Open, Inputs = 0V
VR = 80V, TA = +25°C
VR = 80V, TA = +70°C
Per Output
Note 2.
IF = 350mA
Micrel
Limits
Min. Typ. Max. Units
50 µA
100
0.9
1.1 V
1.1
1.3
1.3
1.6
1.0 V
10.5
8.5
3.5
50
200
kΩ
50
300
50
600
3.3
4.5 mA
3.1
4.5
2.4
3.6
6.4 10.0 mA
6.0
9.0
4.7
7.5
3.0
4.5 mA
2.2
3.6
50 µA
100
500
mA
3.5
4.0
4.5 V
3.0
3.5
4.0 V
7
1.7
2.0 V
165
°C
10
°C
NOTE 1: Operation of these devices with standard TTL or DTL may require the use of appropriate pull-up resistors to insure a minimum logic “1”.
NOTE 2: Under-Voltage Lockout is guaranteed to release device at no more than 4.5V, and disable the device at no less than 3.0V.
Truth Table
INN
Strobe
0
1
Clear
0
1
1
0
X
X
1
X
X
X
X
0
0
X
0
0
X = Irrelevant
t–1 = previous output state
t = present output state
October 1998
Output
Enable
0
0
X
1
0
0
OUTN
t–1
t
X
OFF
X
ON
X
OFF
X
OFF
ON
ON
OFF OFF
Information present at an input is transferred to its latch when
the STROBE is high. A high CLEAR input will set all latches
to the output OFF condition regardless of the Data or STROBE
input levels. A high OUTPUT ENABLE will set all outputs to
the OFF condition, regardless of any other input conditions.
When the OUTPUT ENABLE is low, the outputs depend on
the state of their respective latches. If current shutdown is
activated, the OUTPUT ENABLE must be pulsed high to
restore operation. Over temperature faults are not latched
and require no reset pulse.