Absolute Maximum Ratings(1)
Supply Voltage (VIN) ........................................ −0.3V to +6V
Output Switch Voltage (VSW) ............................. −0.3V to 6V
Sense Input Voltage (VSNS1, VSNS2) ................... −0.3V to VIN
Logic Input Voltage (VEN1, VEN2) ........................ −0.3V to VIN
Storage Temperature Range (Ts)..............–65°C to +150°C
ESD Rating(3)................................................. ESD Sensitive
Operating Ratings(2)
Supply Voltage (VIN)......................................... 2.5V to 5.5V
Sense Input Voltage (VSNS1, VSNS2) ........................ 0V to VIN
Logic Input Voltage (VEN1, VEN2) ............................. 0V to VIN
Junction Temperature (TJ) ..................–40°C ≤ TJ ≤ +125°C
Thermal Resistance
2mm x 2mm Thin MLF-10 (θJA) .........................70°C/W
Electrical Characteristics(4)
TA = 25°C with VIN = VEN1 = VEN2 = 3.6V; L = 1µH; COUT = 4.7µF; IOUT = 20mA; only one channel power is enabled, unless
otherwise specified. Bold values indicate –40°C< TJ < +125°C.
Parameter
Condition
Min. Typ. Max. Units
Under-Voltage Lockout Threshold
(Turn-On)
2.3
2.4 2.485
V
UVLO Hysteresis
60
mV
Quiescent Current
Shutdown Current
VOUT1, 2 (Both Enabled), IOUT1, 2 = 0mA , VSNS1,2 >1.2 ×
VOUT1, 2 Nominal
VEN1, 2 = 0V; VIN = 5.5V
33
50
µA
0.01
4
µA
Output Voltage Accuracy
VIN = 3.6V, ILOAD = 20mA
–2.5
+2.5
%
Current Limit in PWM Mode
SNS = 0.9 × VOUT NOM
0.410 0.62
1
A
Output Voltage Line Regulation
VIN = 3.6V to 5.5V, ILOAD = 20mA
0.4
%/V
Output Voltage Load Regulation
20mA < ILOAD < 400mA, VIN = 3.6V
0.5
%
PWM Switch ON-Resistance
Frequency
Soft-Start Time
Enable Threshold
ISW = 100mA PMOS
ISW = −100mA NMOS
ILOAD = 120mA
VOUT = 90%
0.6
0.8
Ω
4
MHz
260
µs
0.5
0.9
1.2
V
Enable Input Current
0.1
2
µA
Over-Temperature Shutdown
160
°C
Over-Temperature Shutdown Hysteresis
20
°C
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating.
3. Devices are ESD sensitive. Handling precautions recommended. Human body model: 1.5kΩ in series with 100pF.
4. Specification for packaged product only.
May 2010
3