English
Language : 

MIC280_14 Datasheet, PDF (23/28 Pages) Micrel Semiconductor – Precision IttyBitty™ Thermal Supervisor
Micrel, Inc.
Remote Temperature Low Limit Low-Byte Register (TLOW1l) 8-bits, Read/Write
MIC280
D[7]
read/write
Remote Temperature Low Limit Low-Byte Register
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
reserved
D[2]
reserved
D[1]
reserved
Low temperature limit for remote zone, least significat bits. Reserved always reads zero.
D[0]
reserved
Bit
D[7:4]
D[3:0]
Function
Low temperature limit for the remote zone, least significant bits.
Reserved
Operation
Read/write
Always reads as zero
Power-up default value: 0000 0000b = 00h (0°C)
Read/write command byte: 0001 0100b = 14h
Each LSB represents one-sixteenth degree centigrade. The values are in a binary format such that 1/16th°C (0.0625°C) is
reported as 0001 0000b. See Temperature Data Format for more details.
Any writes to a temperature limit register will result in the corresponding fault queue being purged and reset.
Remote Overtemperature Limit Register (CRIT1) 8-bits, Read/Write
D[7]
read/write
D[6]
read/write
Remote Overtemperature Limit Register
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
Overtemperature limit for remote zone.
D[1]
read/write
D[0]
read/write
Bit
D[7:0]
Function
Overtemperature limit for the remote zone.
Operation
Read/write
Power-up default value: 0110 0100b = 64h (100°C)
Read/write command byte: 0001 1001b = 19h
Each LSB represents one degree centigrade. The values are in a two’s complement binary format such that 0°C is
reported as 0000 0000b. See Temperature Data Format for more details.
Any writes to a temperature limit register will result in the corresponding fault queue being purged and reset.
May 5, 2014