English
Language : 

MIC280_14 Datasheet, PDF (17/28 Pages) Micrel Semiconductor – Precision IttyBitty™ Thermal Supervisor
Micrel, Inc.
Status Register (STATUS) 8-bits, Read-Only
MIC280
D[7]
read-only
S7
D[6]
read-only
S6
D[5]
read-only
S5
Status Register
D[4]
read-only
D[3]
read-only
S4
S3
D[2]
read-only
S2
D[1]
read-only
S1
D[0]
read-only
S0
Bit
Function
S7
Data ready
S6
Local high temperature event
S5
Local low temperature event
S4
Remote high temperature event
S3
Remote low temperature event
S2
Diode fault
S1
Remote overtemperature event
S0
Local overtemperature event
Note:
18. All status bits are cleared after any read operation is performed on STATUS.
Operation(18)
1 = data available, 0 = ADC busy
1 = event occurred, 0 = none
1 = event occurred, 0 = none
1 = event occurred, 0 = none
1 = event occurred, 0 = none
1 = fault, 0 = none
1 = event occurred, 0 = none
1 = event occurred, 0 = none
Power-up default value: 0000 0000b = 00h = (no events pending)
Read command byte: 0000 0010b = 02h
The power-up default value is 00h. Following the first conversion, however, any of the status bits may be set depending
on the measured temperature results or the existence of a diode fault.
May 5, 2014
17
Revision 2.0