English
Language : 

MIC3000 Datasheet, PDF (11/68 Pages) Micrel Semiconductor – SFP Management IC
MIC3000
Electrical Characteristics
Micrel
Symbol
Parameter
Condition
Min Typ Max Units
Serial Data I/O Pin, DATA
VOL
Low Output Voltage
VIL
Low Input Voltage
VIH
High Input Voltage
ILEAK
Input Current
CIN
Input Capacitance
Serial Clock Input, CLK
IOL = 3mA
IOL = 6mA
Note 4
0.4
V
0.6
V
0.8
V
2.1
V
±1
µA
10
pF
VIL
Low Input Voltage
VIH
High Input Voltage
ILEAK
Input Current
CIN
Input Capacitance
Serial Interface Timing(4)
2.7V ≤ VDD ≤ 3.6V
2.7V ≤ VDD ≤ 3.6V
Note 4
0.8
V
2.1
V
±1
µA
10
pF
t1
t2
t3
t4
t5
tDATA
CLK (clock) Period
2.5
Data in Setup Time to CLK High
100
Data Out Stable After CLK Low
300
DATA Low Setup Time to CLK Low Start Condition
100
DATA High Hold Time After CLK High Stop Condition
100
Data Ready Time
From power on to completion of one set of
ADC conversions; analog data available via
serial interface.
µs
ns
ns
ns
ns
400 ms
tTO
BUS Timeout
CLK Low
25
30
35
ms
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating.
3. Devices are ESD sensitive. Handling precautions recommended.
4. Guaranteed by design and/or testing of related parameters. Not 100% tested in production.
5. The MIC3000 will attempt to enter its shutdown state when VDD falls below VUVLO. This operation requires time to complete. If the supply voltage falls
too rapidly, the operation may not be completed.
6. Does not include quantization error.
7. Final test on outgoing product is performed at TA = +25°C.
8. The MIC3000 will not respond to serial bus transactions during an EEPROM write-cycle. The host will receive a NACK during tWR.
Timing Diagram
t1
CLK
t4
t2
t5
DATA
(Input)
t3
DATA
(Output)
Serial Interface Timing
October 2004
11
M9999-101204