Parameter
Symbol
Test Conditions
Min Typ Max Units
Input high voltage
Input high voltage
Input low voltage
Input low voltage
SMBus compatible 2-wire interface*
VIH
VIH(Ta,V)
Over temperature and supply
VIL
VIL(Ta,V)
Over temperature and supply
1.6
2
2.4
V
1.2
2
2.8
V
0.7
1.0 1.3
V
0.5
1.0 1.5
V
Output low voltage
VOL
Over temperature and supply, Isink
= 2mA
0.2
V
SCL,SDA leakage
SCL capacitance
SDA capacitance
Slave address
SMBus Request
Timeout,low
Timeout, high
Acknowledge setup time
Acknowledge hold time
Acknowledge setup time
Acknowledge hold time
Ileak
CSCL
CSDA
SA
tREQ
Timeout,L
VSCL=VDD, VSDA=VDD, Ta=+85°C
SCL low
SCL low
Factory default
Timeout,H
Tsuac(MD)
Thdac(MD)
Tsuac(SD)
Thdac(SD)
SCL high
8-th SCL falling edge, Master
9-th SCL falling edge, Master
8-th SCL falling edge, Slave
9-th SCL falling edge, Slave
0.25 uA
10
pF
10
pF
5Bh
hex
21
39
ms
27
32
39
ms
52
64
78
us
TBD
us
TBD
us
TBD
us
TBD
us
Notes: All the communication and refresh rate timings are given for the nominal calibrated HFO frequency and will vary
with this frequency’s variations.
*SMBus compatible interface is described in details in the SMBus detailed description section. Maximum number of
MLX90615 devices on one bus is 127, higher pullup currents are recommended for higher number of devices, faster bus
data transfer rates, and increased reactive loading of the bus.
MLX90615 is always a slave device on the bus. MLX90615 can work in both low-power and high-power SMBus
communication.
All voltages are with respect to the Vss (ground) unless otherwise noted.
3901090615
Rev 001
Page 7 of 30