English
Language : 

MLX92241 Datasheet, PDF (6/16 Pages) Melexis Microelectronic Systems – 2-Wire Hall Effect Switch
MLX92241-AAA
2-Wire Hall Effect Switch
5 Specifications
5.1 MLX92241LUA-AAA-003
DC Operating Parameters VDD = 3.5 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Test
Condition
Operating Point
BOP (mT)
Min
Typ(10)
Max
Release Point
BRP (mT)
Min
Typ(10)
Max
TC
(ppm/oC)
Typ(10)
Ioff
(mA)
Typ(10)
TJ = -40°C
5.9
8.5 10.9 3.5
5.5
7.9
TJ = 25°C
6.1
7.9
9.5 3.9
5.3
7.0
-1100
3.3
TJ = 150°C
3.8
6.8
9.6 2.7
5.0
8.2
5.2 MLX92241LUA-AAA-004
DC Operating Parameters VDD = 3.5 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Test
Condition
Operating Point
BOP (mT)
Min
Typ(10)
Max
Release Point
BRP (mT)
Min
Typ(10)
Max
TC
(ppm/oC)
Typ(10)
Ioff
(mA)
Typ(10)
TJ = -40°C
6
9.2
12
5
7.2 10.5
TJ = 25°C
6
9.2
12
5
7.2 10.5
0
6
TJ = 150°C
5.7
9.2
12.5 4.6
7.2
11
Output Polarity
& Active Pole
Direct
South pole
Output Polarity
& Active Pole
Inverted
South pole
5.3 MLX92241LUA-AAA-005
DC Operating Parameters VDD = 3.5 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Test
Condition
Operating Point
BOP (mT)
Min
Typ(10)
Max
Release Point
BRP (mT)
Min
Typ(10)
Max
TC
(ppm/oC)
Typ(10)
Ioff
(mA)
Typ(10)
TJ = -40°C
6
9.2
12
5
7.2 10.5
TJ = 25°C
6
9.2
12
5
7.2 10.5
0
3.3
TJ = 150°C
5.7
9.2
12.5 4.6
7.2
11
Output Polarity
& Active Pole
Inverted
South pole
5.4 MLX92241LUA-AAA-006
DC Operating Parameters VDD = 3.5 to 24V, TJ = -40°C to 165°C (unless otherwise specified)
Test
Condition
Operating Point
BOP (mT)
Min
Typ(10)
Max
Release Point
BRP (mT)
Min
Typ(10)
Max
TC
(ppm/oC)
Typ(10)
Ioff
(mA)
Typ(10)
TJ = -40°C
5.9
8.5 10.9 3.5
5.5
7.9
TJ = 25°C
6.1
7.9
9.5 3.9
5.3
7.0
-1100
6
TJ = 150°C
3.8
6.8
9.6 2.7
5.0
8.2
Output Polarity
& Active Pole
Direct
South pole
10 Typical values are defined at TA = +25°C and VDD = 12V, unless otherwise specified
390109224100 Rev. 1
Page 6 of 16
June/13